DIP SWITCH SET-UP PROCEDURES
Page 28
6.2 N
UMBER
OF
S
CREWS
S
ELECTION
[S
INGLE
/T
WIN
,
ETC
]
Set the SW1 Dip Switches on the Processor Main Circuit Boards using
the following steps:
A)Place the System in Set-up Mode by following Section 6.1.5,
B)Refer to the Figure 18: for the correct Dip Switch setting.
•Refer to Figure 14:, page 25, for the location of the Dip
Switch.
C)Store the value that has been set by following Section 6.1.6,
D)If Dip Switch R7 has been used during the Set-up, ensure
R7 is in the fully counterclockwise position.
E)Place Jumper 2 in the Open State .
• A low repetitious rate tone is heard indicating that the Con-
trol System is out of Set-up Mode and no Station is in com-
mand.
F) Take command at a Station.
• The red LED will light; indicating Station is in command
CAUTION: The Number of Screws setting MUST be made before setting the System ID # of each
Processor.
CAUTION:The settings on all Processors Main Circuit Boards MUST be set the same for Twin
Screw or more applications.
Figure 18: Dip Switch Setting Number of Screw5)
0657-600
1
23
45
6
7
OFF
To change, use a
small screwdriver.
PUSH DOWN
FOR ‘ON’
PUSH DOWN
FOR ‘OFF’
OFF
OFF
OFF
OFF
OFF
OFF
ON
Single Screw
0657-600
1
2
34
5
6
7
OFF
PUSH DOWN
FOR ‘ON’
PUSH DOWN
FOR ‘OFF’
OFF
OFF
OFF
OFF
OFF
OFF
ON
Twin Screw (or more)
FACTORY DEFAULT
Summary of Contents for ClearCommand
Page 56: ......
Page 57: ...APPENDIX A 1 ...
Page 58: ......
Page 60: ...Appendix A 6 20 01 Page 2 ...
Page 63: ...Page 5 ...
Page 64: ...Page 6 ...
Page 68: ...Page 10 ...
Page 70: ...Page 12 ...
Page 72: ...Page 14 ...
Page 78: ...Page 20 ...
Page 82: ...Page 24 ...
Page 85: ...APPENDIX B 1 ...
Page 86: ......
Page 97: ...APPENDIX C 1 ...
Page 98: ......
Page 99: ...Drawing 11202F 1 ...
Page 100: ... ...
Page 101: ...Drawing 11202F 2 ...
Page 102: ... ...
Page 103: ...Drawing 11202F 3 Notes Page ...
Page 104: ... ...