LCD Display Signal
SYMBOL
DESCRIPTION
Systolic blood pressure
Diastolic blood pressure
EXPLANATION
Current Time
Time(year:month:day:hour:minute)
mmHg
Heartbeat
INTRODUCTION
CAUTION
INTRODUCTION
Average value
The average value of lastest 3 groups
value blood pressure
Low battery indicator
Batteries are running low and need to be
replaced
Motion indicator
Motion may result in an inaccurate
measurement
High blood pressure
Low blood pressure
Pulse in beats per minute
Pulse display
Measurement Unit of the blood pressure
(1mmHg=0.133kPa)
Blood pressure monitor is detecting an irregular
heartbeat during measurement.
Irregular heartbeat Detection
Blood pressure monitor is detecting a heartbeat
during measurement.
Data pending to transmit
Measurement data stored in the equipment
Bluetooth icon
The Bluetooth icon blinks when the Bluetooth
is working
* The service life of the cuff may vary by the frequency of washing, skin condition, and
storage state. The typical service life is 10000 times.
* It is recommended that the performance should be checked every 2 years and after
maintenance and repair, by retesting at least the requirements in limits of the error of the cuff
pressure indication and air leakage (testing at least at 50mmHg and 200mmHg).
* Please dispose of ACCESSORIES, detachable parts, and the ME EQUIPMENT according
to the local guidelines.
* Manufacturer will make available on request circuit diagrams, component part lists,
descriptions, calibration instructions,etc., to assist to service personnel in parts repair.
* The plug/adapter plug pins insulate the device from the main supply. Do not position the
device in a position where it is difficult to disconnect from the supply mains to safely
terminate operation of ME equipment.
* The operator shall not touch output of batteries /adapter and the patient simultaneously.
* Cleaning :Dust environment may affect the performance of the unit. Please use the soft
cloth to clean the whole unit before and after use. Don’t use any abrasive or volatile
cleaners.
* The device doesn’t need to be calibrated within two years of reliable service.
* If you have any problems with this device, such as setting up, maintaining or using, please
contact the SERVICE PERSONNEL of ZEWA. Don’t open or repair the device by yourself in
the event of malfunctions. The device must only be serviced, repaired and opened by
individuals at authorized sales/service centers.
* Please report to ZEWA if any unexpected operation or events occur.
* Keep the unit out of reach of infants, young children or pets to avoid inhalation or
swallowing of small parts. It is dangerous or even fatal.
* Be careful to strangulation due to cables and hoses, particularly due to excessive length.
* At least 30 min required for ME equipment to warm from the minimum storage temperature
between uses until it is ready for intended use. At least 30 min required for ME equipment to
cool from the maximum storage temperature between uses until it is ready for intended use.
* This equipment needs to be installed and put into service in accordance with the
information provided in the ACCOMPANYING DOCUMENTS;
* Wireless communications equipment such as wireless home network devices, mobile
phones, cordless telephones and their base stations, walkie-talkies can affect this
equipment and should be kept at least a distance d away from the equipment. The distance
d is calculated by the MANUFACTURER from the 80MHz to 5.8 GHz column of Table 4 and
Table 9 of IEC 60601-1-2:2014, as appropriate.
* Please use ACCESSORIES and detachable parts specified/ authorised by
MANUFACTURE. Otherwise, it may cause damage to the unit or danger to the
user/patients.
* There is no luer lock connectors are used in the construction of tubing, there is a possibility
that they might be inadvertently connected to intravascular fluid systems, allowing air to be
pumped into a blood vessel.
* Please use the device under the environment which is provided in the user manual.
Otherwise, the performance and lifetime of the device will be impacted and reduced.