2
M
OUNTING THE
S
YSTEM
The system should be attached to a secure and stable structure so that there is good visibility
of the output display. The means of mounting will be dependent on the specific application,
however using a worm drive hose clip (such as a Jubilee® clip) to secure the cylindrical body of
the system to channel section proves an effective method.
The 4 Digit Subsea Display (
not dual
) may also be mounted within a Remote Actuator
Assembly, Part No: 023-14-16-002, that provides a facility for switching the zero display,
scaling and units functions. If this is the case the system will be mounted directly to the
Remote Actuator as detailed in the General Assembly Drawing, Doc. No: 023-14-16-001, which
in turn should be mounted using the 2 off mounting holes on the front flange. The position and
size of these mounting holes are detailed in the General Assembly Drawing. Consideration
should be made to the mounting position to allow the actuator levers to be operated.
If a Remote Actuator Assembly is required for a Dual 4 Digit Subsea Display, then please
contact Zetechtics.
Note
: Adapter holes are provided on the Remote Actuator to allow for mounting of adapter
levers (not supplied by Zetechtics).
If the front glass of the 2 digit display is scratched or otherwise damaged, the Unit should be
returned to Zetechtics for replacement/pressure testing.