ChilliNet
Spice dimmers can be connected to Chilli Control Panels over ChilliNet. Other
are also
compatible. Each device has a set of network terminals or an RJ11 socket provided for connection to the Chillinetwork.
The cable used to connect the various devices in the network must be CAT 5 (100MHz) FTP cable. Alldevices in the
Chilli network must be connected in serial. The devices in the network can be wired in any order. Anetwork termination
resistor must be fitted at the two ends of the Chilli network.
ChilliNet Connections
Two RJ11 sockets are provided on the Spice dimmer for connection to
the ChilliNet network.
This diagram shows the wiring details for the RJ11 connector. Note
that only the central four pins should be connected as shown.
Zero 88 - Spice - Page 9 of 47
Printed: 10/03/2021 09:32:33 ES