Select the Manual Control option from the top level menu options, and press the ENT key to enter the Manual
Control menu. The following options are available:
Use the cursor keys to scroll between the options. Press the ENT key to enter the menu for the selected option.
Set Channel Level
This option allows you to set up a manual control level between 0 - 100% for each of the dimmer channels.
Select the Set Chan Level option from the menu, and press the ENT key to enter the menu.
Standard mode
When operating in Standard mode, the screen shows:
Channel: xx
Level: xxx
The cursor is shown in the Channel field. The channel number defaults to 1.
ChilliNet mode
When operating in ChilliNet mode, the screen shows:
A (xx) Channel: xx
Level: xxx