The cursor is in the Area field. Enter the required area number using the numeric keypad or cursor keys, then pressthe
ENT key.
If the area number is valid, the cursor moves to the Memory field.
If a memory for the selected area is currently being output from the dimmer, then that number is shown.
Use the numeric keypad or cursor keys to select a memory to be output (0 - 12).
Press the ENT key to confirm the memory number selection.
The dimmer sends out the corresponding Play Memory / Area message onto the network.
If the dimmer has one or more channels assigned to the specified area it performs the following:
Memory Zero - The outputs fade to zero in 3 seconds, and replace any previous memory or sequence being
output for the selected area.
Programmed Memory - The outputs fade to those in the selected memory in the memories fade time, and
replace any previous memory or sequence being output for the selected area.
Unprogrammed Memory – * is displayed and the outputs do not change.
The screen returns to the Play Memory screen.
In ChilliNet mode, a dimmer can only play back one memory per area at a time, but may play back up to ten different
memories if they are all in different areas.
Clear Memories
Standard Mode
This option allows you to clear all the 12 memories in the dimmer.
Select the Clear Memories option from the Memories menu, and press the ENT key. The screen shows:
Press ENT key to
clear memories
Press the ENT key to clear all the memories and any programmed sequences in the dimmer.
The screen returns to the Memories screen.
ChilliNet Mode
This option allows you to clear all the 12 memories for a specified area in the dimmer.
Select the Clear Memories option from the Memories menu, and press the ENT key. The screen shows:
Zero 88 - Spice - Page 21 of 47
Printed: 10/03/2021 09:32:33 ES