AqueenaPro WT-100
Installation and Repair manual
Rev. A
Installation and Repair Manual AqueenaPro WT-100
Page 63 of 64
6. Disconnect the pump (25).
ATTENTION!
Pay attention how wires are connected. Always connect red+ green, black + brown. Use the
clamps as protection,
7. Disconnect the power cord (44).
ATTENTION!
To connect the wires back, pay attention to correct pair grey+red, brown + black.
Use clamps as protection.
8.
Exchange the colour wire set to new one.
9. Connect all elements back
a) Control board
b) Inlet solenoid valve (33) - orange
c) Low pressure switch (22) – yellow
d) Flashing valve (32) – white