11. Tools
Flathead screwdriver 3x75
Philips screwdriver PH2
Allen key
CH17,19
Pliers
water, the
machine starts
repeatedly
System is exhibiting a loss of pressure
After checking the non return valve,
check whether there is water leakage
in the pipelines
The pure water
flow is small or
not flowing
Pre-filter is plugged
Replace the pre-filter
RO membrane is plugged
Wash or replace the RO membrane
Inlet solenoid valve failure
Replace the inlet solenoid valve
Non return valve is plugged
Replace the non return valve
Post-carbon filter is plugged
Replace the post-carbon filter
High pressure pump pressure is not
enough
Measure the high pressure pump
water pressure, replace if needed