AqueenaPro WT-100
Installation and Repair manual
Rev. A
Installation and Repair Manual AqueenaPro WT-100
Page 58 of 64
9. Replace the pump.
ATTENTION!
Pay attention how wires are connected. Always connect red+ green, black + brown. Use the
clamps as protection,
To assemble the new pump back follows the steps in reverse order.
When water pipes are connected pay attention to correct water flow.
Remember!
Grey connector – water flow in
White connector – water flow out