33
Function, operation
SLIDER IN
6
Slider in
Fold in the platform. Push button 6 (arrow
right) at which the platform takes transport
position under body.
Operating slider, 6 buttons
Tilt up
Push button (1) and button (4). If the load
is to heavy or placed to far back on the
platform at tilt up, the overflow valve opens.
Lift
Push button (1) and button (3). The platform
lifts with the same speed. If the load is to
heavy the over flow valve opens.
TILT
UP
1+4
LIFT
1+3
OPERATING INSTRUCTION
The tail lift can only be used by authorized
personnel.
DO NOT OVERLOAD THE TAIL LIFT!
After operating the tail lift
Lock the platform, turn of the maneuver
current in the cabin. Then the tail lift is
locked for unauthorized people. If the
platforms lock handle (if available) goes
heavily, the reason can be hose break at
the lift or tilt system.
Note!
Certain models of control units are
equipped with electric heating. The electric
heating is connected to the control current.
This will consume a little current from the
battery if the control current is switched on.
NOTE!
The hydraulic system is
protected against overload
at lift and tilt up of a built in
overflow valve. Notice that this
valve doesn’t protect at resting
or lowering. This may under
no circumstances be used for
overloading at lowering.
NOTE!
The platforms movement can
stop at anytime (if the push
buttons are released) and in
all positions because the push
buttons break the current to
respective function.
NOTE!
Always lift up the platform
against body floor before tilt
up/closing to transport position.