3
6.
Cautions
1,
Never remove any connecting parts when the tank is under
pressure.
2,
Never remove any electrical parts before isolating the
electrical supply.
3,
Never adjust the pressure switch unnecessarily
4,
Always ensure that the electrical supply is sufficient for the
compressor.
5,
Never use the electrical plug to start or stop the compressor.
6,
If the pressure switch isn’t working, switch off the machine
immediately to reduce any long term damage.
7,
Replacement lubricant must be new and clean and should be
filled to the red cycle of the oil site glass.
8,
Be sure to drain the tank daily.
9,
Check oil level daily.
7.
Maintenance
1,
Clean crankcase and renew lubricant oil after the first 10
working hours.
2,
Remove the drain valve to remove water from the tank daily
3,
Replace air filters every 120 hours of use or as and where
they require replacement.