background image

 

6.  

Cautions 

 

1,   

Never remove any connecting parts when the tank is under 

 

 

pressure. 

2,   

Never remove any electrical parts before isolating the  

 

 

electrical supply. 

3,   

Never adjust the pressure switch unnecessarily  

4,   

Always ensure that the electrical supply is sufficient for the 

 

 

compressor. 

5,   

Never use the electrical plug to start or stop the compressor. 

6,   

If the pressure switch isn’t working, switch off the machine 

 

 

immediately to reduce any long term damage. 

7,   

Replacement lubricant must be new and clean and should be 

 

 

filled to the red cycle of the oil site glass.  

8,   

Be sure to drain the tank daily. 

9,   

Check oil level daily. 

 

 
 
7.  

Maintenance 

 

1,   

Clean crankcase and renew lubricant oil after the first 10  

 

 

working hours. 

2,   

Remove the drain valve to remove water from the tank daily 

3,   

Replace air filters every 120 hours of use or as and where 

 

 

they require replacement. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for ZC350

Page 1: ...Air Compressor Operation Manual ZC350 Before operation be familiar with the operation manual first...

Page 2: ...1 3 Technical Specification Page 1 4 Preparation before Starting Page 2 5 Operation and Adjustment Page 2 6 Cautions Page 3 7 Maintenance Page 3 8 Trouble Shooting Page 4 9 Parts Illustration Page 5...

Page 3: ...er fields where compressed air is required 2 General View and Main Components Fig 1 1 Pump 2 Pressure Switch 3 Outlet Valve 4 Regulating Valve 5 Pressure gauge 6 Non Return Valve 7 Drain Valve 8 Wheel...

Page 4: ...below 10 deg 11 Set the pressure switch to the On position Fig 2 let the compressor run for 10 minutes with no load to ensure lubrication of the moving parts before regular operation 5 Operation and A...

Page 5: ...stop the compressor 6 If the pressure switch isn t working switch off the machine immediately to reduce any long term damage 7 Replacement lubricant must be new and clean and should be filled to the r...

Page 6: ...or abnormal noise 1 Connecting parts loose 2 Foreign object is the pump 3 Piston hitting valve seat 4 Moving parts worn 1 Check and retighten 2 Check and Clean 3 Replace with thicker gasket 4 Repair o...

Page 7: ...5 9 Parts Diagram...

Page 8: ...4 16 Rubber gasket 1 53 Discharge pipe 1 17 Crank case cover 1 54 Bolt M8x25 4 18 Bolt M5x16 6 55 Non return valve 1 19 Oil sight glass gasket 1 56 Axle 2 20 Oil sight glass 1 57 Axle set 2 21 Bolt M6...

Page 9: ...d cooling airflow All single phased compressors fitted with a 13amp plug are designed to plug directly in to a standard 13amp socket Exclusion to warranty cover are detailed below A The cost of routin...

Reviews: