Touch Control
A – Lights Button:
Lights are three level (high, medium, low). From off, touch once for
high, twice for medium, three times for low, four times to cycle back to off. Press and
hold for 3 seconds to turn on/off the back wall lighting.
B - Delay Off Button:
Press this button to enable the ten-minute delay-off function. After
ten minutes the fan and all lights will turn off. The delay-off function can be enabled
no matter at what speed the fan is on. Delay off function can be turned off by pressing
the Delay Off Button, changing the speed, or pressing the Power Button C.
C - Power Button:
Short press will turn on and off the fan and all lights. When pressed,
the button illuminates for 1 second, then the button light turns off. Hood will remember
the last speed and light level it was last turned off at.
D – Low Speed Button:
Press once for low speed.
E – Medium Speed Button:
Press once for medium speed.
F – Hight Speed Button:
Press once for high speed.
MESH FILTER CLEAN REMINDER
(always enabled): after 60 hours of fan usage, button
A blinks when the hood is on, indicating it is time to clean the mesh filters.
To Reset the function: with the hood on, press and hold the B button for 4 to 5 seconds,
the A button will stop blinking, and the 60-hour timer will reset.
CHARCOAL FILTER REPLACE REMINDER
(disabled by default, must be enabled by user
if recirculating hood): To enable Charcoal Filter Replacement Function hold buttons D
and F simultaneously for four seconds. The A button will quickly flash 3 times indicating
the Charcoal Filter Replacement Function is enabled. After 200 hours of fan usage, the B
button will blink while the hood is on, indicating it is time to replace the charcoal filters.
To Reset the Charcoal Filter Replace Reminder function: Hold the B button for 4 to 5
seconds until it stops flashing, and the 200-hour timer will reset.
Order replacement charcoal filter kit number Z0F-C010 through your local dealer, www.
zephyronline.com, or the Zephyr customer service department.
To disable the Charcoal Filter Replacement function, repeat the enable procedure, the A
button will illuminate for 3 seconds then turn off indicating the Charcoal Filter Replace-
ment Function is disabled.
CLEAN AIR FUNCTION
(disabled by default, must be enabled by the user). To enable
Clean Air function, with hood off, press and hold button E for 4 to 5 seconds. The E button
will start blinking, the fan will turn on low speed for 10 minutes. After 10 minutes the
fan will turn off and the 4-hour timer will begin. The E button led will continue blinking
when Clean Air Function is enabled, even if fan is not on. When Clean Air function is
enabled, every 4 hours of non-fan usage the fan will automatically turn on at low speed
for 10 minutes. After 10 minutes the fan will turn off and the 4-hour timer will reset.
A
B
C
D
E
F
- 22 -
Summary of Contents for HORIZON DHZ-M90AMWX
Page 2: ......
Page 25: ...Wiring Diagram INTERNAL BLOWER CIRCUIT DIAGRAM 25 ...
Page 26: ...Wiring Diagram REMOTE BLOWER CIRCUIT DIAGRAM 26 ...
Page 29: ......
Page 54: ...Schéma de câblage SCHÉMA DU CIRCUIT DE MOTEUR INTERIEUR 54 ...
Page 55: ...Schéma de câblage SCHÉMA DU CIRCUIT DE MOTEUR EXTERIEUR 55 ...
Page 58: ......
Page 59: ......