NOTE! The device in this version
(with external blower) is equipped for
rear discharge of exhaust air. However,
if required, it is possible to have the
exhaust air discharged from the top.
This can be accomplished by carrying
out the steps indicated in the follow-
ing paragraphs; upon reaching step 5,
the blower plate must be rotated and
installed in the opposite direction.
The following instructions are for preparing the hood for use with an ex-
ternal or in-line blowers models CBE-1000 or PBN-1000A.
CAUTION: To reduce the risk of fire and electric shock, install this rangehood
only with remote blowers rated maximum 6.2 A.
For internal blower instructions please turn to page 11.
1. Unclip the top cover. Fig.1
2.
Remove the metal blower plate by
striking it with the aid of a slotted
screwdriver Fig.2
3. Remove the (6) screws securing the
blower plate to the blower housing
and remove blower plate. See.Fig.3
4. Install the flange and fix it to the blower
plate with the (4) screws. Fig 4
Installation - External & In-Line Blower
Preparation
- 14 -
Summary of Contents for HORIZON DHZ-M90AMWX
Page 2: ......
Page 25: ...Wiring Diagram INTERNAL BLOWER CIRCUIT DIAGRAM 25 ...
Page 26: ...Wiring Diagram REMOTE BLOWER CIRCUIT DIAGRAM 26 ...
Page 29: ......
Page 54: ...Schéma de câblage SCHÉMA DU CIRCUIT DE MOTEUR INTERIEUR 54 ...
Page 55: ...Schéma de câblage SCHÉMA DU CIRCUIT DE MOTEUR EXTERIEUR 55 ...
Page 58: ......
Page 59: ......