Installation –
Mounting Height & Clearance
6
www.zephyronline.com
DUCTING
A minimum of 8” round or 3-1/4” x 10” rectangular
GXFWPXVWEHXVHGWRPDLQWDLQPD[LPXPDLUÀRZ
HႈFLHQF\IRUVLQJOHEORZHUDQG´URXQGGXFWIRU
dual blower.
Always use rigid type metal ducts only. Flexible
GXFWVFRXOGUHVWULFWDLUÀRZE\XSWR
$OVRXVHFDOFXODWLRQRQSDJHWRFRPSXWHWRWDO
available duct run when using elbows, transitions
and caps.
ALWAYS, when possible, reduce the number or
transitions and turns. If long duct run is required,
increase duct size from 8” to 10”.
If turns or transitions are required; install as far
away from hood duct output and as far apart,
between the two as possible.
Minimum mount height between range top to hood
bottom should be no less than 26”.
Maximum mount height should be no higher than
36”.
It is important to install the hood at the proper
mounting height. Hoods mounted too low could
UHVXOWLQKHDWGDPDJHDQG¿UHKD]DUGZKLOH
hoods mounted too high will be hard to reach and
ZLOOORVHLWVSHUIRUPDQFHDQGHႈFLHQF\
If available, also refer range manufacturer’s height
clearance requirements and recommended hood
mounting height above range.
Vertical Ducting:
´URXQGPLQLPXPVLQJHEORZHU
´URXQGPLQLPXPGXDOEORZHU
Horizontal Ducting:
´[´PLQLPXPVLQJOHEORZHU
´URXQGPLQLPXPVLQJOHEORZHU
No horizontal option available for dual blower
DAMAGE-SHIPMENT / INSTALLATION:
• Please fully inspect unit for damage before
installation.
• If the unit is damaged in shipment, return the
unit to the store in which it was bought for
repair or replacement.
• If the unit is damaged by the customer, repair
or replacement is the responsibility of the
customer.
,IWKHXQLWLVGDPDJHGE\WKHLQVWDOOHULIRWKHU
WKDQWKHFXVWRPHUUHSDLURIUHSODFHPHQW
must be made by arrangement between
customer and installer.
36”
26” min.
36” max.