ZENN
iO
AVANCE Y TECNOLOGÍA
vwww.zennio.com
22
22
ANNEX I. INSTALLATION SCHEME
Figure 4.1 shows a typical scheme of an installation with 3 different climate zones, controlled
by an IRSC-Zone.
Figure 4.1. Scheme. Installation example
The IRSC interface (programmed with the IRSC-Zone application program) carries out the
thermostatic control of the installation by receiving data from an external touch panel (InZennio Z38i
or InZennio Z41) and from a sensor (QUAD), which measures the temperatures of the different
enabled zones in the installation. With this input data, and according to the configuration
parameterized in ETS, IRSC-Zone will send orders, via IR commands, to the central A/C machine to
acclimatize the installation zone by zone, as desired.
To achieve an optimal acclimatization, it is recommended to install the external sensor in the inner
side of the returning pipe, as closest as possible to the central A/C machine.