803341NZ - HydroTap Taps Install Instructions 09.18 v2.11  

Page 9 of 24

    Installation Instructions - HydroTap Arc / Cube

A

A

Left Hand Control

Right Hand Control

B

C

C

B

50mm

2.2

  Height adjustment (Fixed position options)

O-RING

LOWER 

RUBBER 

WASHER

METAL WASHER

NUT

2.4

  Mounting

Cut a 35mm hole in the bench / sink top.

BENCH TOP

Ø35mm

NOTE:

 To reduce the risk of scalding, 

Position A should not be selected 

with Boiling Water units.

2.3

  Angular adjustment (Fixed position options)

Summary of Contents for HydroTap Elite

Page 1: ...s Install Instructions 09 18 v2 11 Page 1 of 24 Installation Instructions Zenith HydroTap Taps HydroTap Classic HydroTap Elite HydroTap Arc Cube Classic All In One Celsius All In One Celsius Arc Cube Mixer Classic Arc Cube ...

Page 2: ...Page 2 of 24 803341NZ HydroTap Taps Install Instructions 09 18 v2 11 Notes ...

Page 3: ...HydroTap Taps Install Instructions 09 18 v2 11 Page 3 of 24 1 HydroTap Classic Elite 6 2 HydroTap Arc Cube 8 3 Mixer Tap 12 4 Classic All In One Tap 14 5 Celsius All In One Tap 18 6 Celsius Arc Cube 21 Contents ...

Page 4: ... Cube are standalone taps compatible with the HydroTap undersink unit offering instant boiling chilled and or sparkling water Classic Arc and Cube Mixer Tap range may be used in conjunction with the standalone taps above to provide mixed hot and cold water Classic All In One and Celsius All In One offer combinations of boiling chilled and or sparkling together with an integral mains water mixer ...

Page 5: ...s are provided for the installation of HydroTap taps only This book must be read in conjunction with the undersink HydroTap Installation Manual and the User Manual For new installations it is recommended to fit the tap prior to installing the undersink unit Special Tools Required In addition to normal tools the following will be required 35mm 50mm diameter sheet metal hole punch for sink tops not ...

Page 6: ... washer is formed similarly to a spring washer It will flatten once the assembly is tightened Note feed each of the three tubes and USB cable evenly in between the legs of the spider clamp Note If the flow rate is too fast insert the Teflon restrictor into the silicon Hot Outlet tube 6mm NUT SPIDER CLAMP STAINLESS STEEL WASHER 1 HydroTap Classic Elite HydroTap Classic Elite 1 1 Position the tap su...

Page 7: ...se to Vent 1 3 Typical HydroTap Installation RED CLEAR BLUE BRAIDED USB CHILLED OUTLET MAINS IN MIXER OUT MIXER IN BOILING OUT BYPASS IN VENT BYPASS OUT Note All silicon tubes must be cut to size They must have a constant fall back to the unit Note Mains hose length is 750mm Plug and cord length is 1800mm Position the under sink unit close to the outlet tap within reach of the hose and cord length...

Page 8: ...oles are required for the new spout height and orientation check the new plastic clip position will clear the undercut and that the wiring loom will not be pinched when assembled 4 Slide the plastic clip up down to engage with the selected holes making sure the two dimples engage simultaneously with the two selected holes NOTE The clip will not fit correctly if one dimple engages before the other ...

Page 9: ...rol Right Hand Control B C C B 50mm 2 2 Height adjustment Fixed position options O RING LOWER RUBBER WASHER METAL WASHER NUT 2 4 Mounting Cut a 35mm hole in the bench sink top BENCH TOP Ø35mm NOTE To reduce the risk of scalding Position A should not be selected with Boiling Water units 2 3 Angular adjustment Fixed position options ...

Page 10: ... Sparkling Used with BCS only Type B Chilled Type A Boiling Type D Sparkling Type E Chilled Ambient Red Silicon Blue Silicon Blue White LLDPE White LLDPE Blue LLDPE Type F S S Tube Three way silicon tube S S tube 20mm insertion Fig 1 Clamp Herbie clip near the end of the three way silicon tube Fig 2 General Fitting Instructions Once the ARC and CUBE HydroTaps have been secured to the benchtop or s...

Page 11: ...a 1 Area 2 BOILING CHILLED SPARKLING BOILING CHILLED BOILING AMBIENT BOILING CHILLED SPARKLING CHILLED Pre cut edge on backing paper Outer edge Outer edge 2 6 Attach Label Working from inside the cupboard follow the directions for the relevant installation Boiling Kit Fit the Type A tube assembly into the L H or R H side of the three way silicon tube Fit the Type F tube into the other side of the ...

Page 12: ...tight seal Pass the tap tubes and threaded extension through the 35mm hole and position the tap so that it discharges into the sink Fit the lower rubber washer to the threaded extension Secure the tap in position with the metal washer and nut Affix the three hoses to the tap Match the hose colours to the coloured bands on the copper extension tubes Arc Mixer Tap For use with Classic or Arc HydroTa...

Page 13: ...ue BOILING OUT BYPASS IN VENT BYPASS OUT Note Mains hose length is 750mm Plug and cord length is 1800mm Position the under sink unit close to the outlet tap within reach of the hose and cord lengths supplied Note All silicon tubes must be cut to size They must have a constant fall back to the unit Note The mixer tap requires a flow restrictor valve supplied to be fitted in the cold water supply li...

Page 14: ...and position the tap so that it discharges into the sink Thread the cable and silicon tubes through the circular clamp block see figures 4 3 4 5 and fix with nut Affix the braided hoses see figures 4 4 4 5 For A I O tap 50mm hole Double Bowl 4 1 SINK TOP 50mm Classic All In One Tap Vented or Mains Position the tap such that it dispenses into the sink bowl with ample clearance for a cup or tea pot ...

Page 15: ...the hoses are lubricated prior to assembly Check the correct position for Hot and Cold connections by matching the colours on the braided hoses with the coloured markings on the copper extension tubes and on the clamp block as indicated Make sure all tubes and hoses are firmly secured Test for leaks after all the connections have been secured Vented braided hose positions 4 4 Affix Braided Hoses t...

Page 16: ... connection Mains IN To Mixer IN R R C B B Vented Mains Assembled Clamp Block Note If the flow rate is too fast a teflon flow restrictor is provided with the tap Cut the red silicon tube 75mm minimum from the bottom of the base of the All In One tap Insert the Teflon Restrictor about 20mm into the upper seg ment of the red silicon tube which connects to the tap Insert the black plastic outlet bush...

Page 17: ... connector strainer supplied Booster RED CLEAR BLUE BRAIDED USB CHILLED OUTLET MAINS IN MIXER OUT MIXER IN BOILING OUT BYPASS IN VENT BYPASS OUT Note Mains hose length is 750mm Plug and cord length is 1800mm Position the under sink unit close to the outlet tap within reach of the hose and cord lengths supplied Note All silicon tubes must be cut to size They must have a constant fall back to the un...

Page 18: ...he steel washer and large nut from inside the cupboard space Connect silicon hoses to the 3 way tube as shown in Fig 5 3 5 4 Affix the braided hoses for hot and cold mains water supply For Celsius A I O Tap 50mm hole Double Bowl O RING SEAL BLACK RUBBER SEAL STEEL WASHER BRASS NUT USB PLUG HOT COLD BRAIDED HOSES Position the tap such that it dispenses into the sink bowl with ample clearance for a ...

Page 19: ...IG 5 4 FROM STEAM VENT OUTLET OF UNDERSINK UNIT 3 WAYS MULTI CHANNEL BOTTOM END OF 3 WAY TUBE 3 STAINLESS STEEL TUBES STEAM VENT BOILING OUTLET CHILLED OUTLET BRASS NUT USB PLUG COLD MAINS HOT MAINS JG STRAIGHT CONNECTOR BRAIDED HOSE FOR MIXED WATER BOILING STEAM VENT CHILLED SPARKLING JG Straight Connector LLDPE Tube Y connector 5 4 BCS MODEL Installation Instructions Celsius All In One Tap BC MO...

Page 20: ...ce and connector strainer supplied Booster RED CLEAR BLUE BRAIDED USB CHILLED OUTLET MAINS IN MIXER OUT MIXER IN BOILING OUT BYPASS IN VENT BYPASS OUT Note Mains hose length is 750mm Plug and cord length is 1800mm Position the under sink unit close to the outlet tap within reach of the hose and cord lengths supplied Note All silicon tubes must be cut to size They must have a constant fall back to ...

Page 21: ... punch for sink tops not supplied 35mm diameter hole saw for timber bench tops not supplied 42mm AF tube spanner or wrench not supplied for fixing tap assembly 6 Celsius Arc Cube BENCH TOP Ø35mm 35mm hole Double Bowl 6 1 Position the tap such that it dispenses into the sink bowl with ample clearance for a cup or tea pot Cut a 35mm hole in the bench sink top Celsius Arc Celsius Cube ...

Page 22: ...ing model Vent outlet 6 2 Connect the Chilled Tube from the tap via the Y Connector to the Chilled and Spar kling tubes to the undersink unit Pass all the hoses tubes and USB lead through the 35mm hole Ensure the black rubber seal is correctly positioned to give a water tight seal Secure the rubber brass washers and large brass nut from inside the cupboard space Affix the braided hoses for hot and...

Page 23: ... connector strainer supplied RED CLEAR BRAIDED USB MAINS IN MIXER OUT MIXER IN BOILING OUT BYPASS IN VENT BYPASS OUT Note Mains hose length is 750mm Plug and cord length is 1800mm Position the under sink unit close to the outlet tap within reach of the hose and cord lengths supplied Note All silicon tubes must be cut to size They must have a constant fall back to the unit ...

Page 24: ...l 0800 558 055 As Zenith policy is one of continuous product improvement changes to specifications may be made without prior notice Images in this booklet have been modified and may not be true representations of the finished goods The terms Zenith and HydroTap are registered trade marks of Zenith Heaters Ltd Products described in this publication are manufactured under one or more patents and fur...

Reviews: