206-3492-A
Accessing the Installer Menu
The Installer menus are accessed by using the remote control. Just press
and hold MENU (about 8 seconds) until the display changes, then press 9,
8, 7, 6, then ENTER. To exit the Installer Menu, press ENTER again.
Any
changes you make will be stored in nonvolatile memory.
The Installer Menu opens with item 03 VERT POS. Press the Up/Down arrow
keys to sequence through the various items. Or, access an item directly by
entering the line number, then pressing MENU. For example, to access the
Start channel/volume feature which is on line 10, press 10, then MENU. To
change a current setting use the Left/Right ADJ keys.
Using the Installer Menu
Items 00-27 are immediately accessible only upon entering the Installer
Menu. Their numbers, descriptions, ranges, factory default settings, and a
place for listing any changes made on-site are given below. A second sec-
tion of the Installer Menu that is intended for qualified service technicians
only is not shown (items 28-201). Normally these items do not require
adjustment.
Options in the Installer Menu:
Installer Menus
1391-00
01.19 V 01
03 VERT POS
15
XX/XX/9X
TE11111111
Use the Installer Menus to make adjustments to operational settings
Installer should leave item 00 FACT MODE
set to 0 (default).
Items 28-201 are ser-
vice-type adjustments and only qualified
technicians having specialized test equip-
ment should access them.
I
tem
Description
Range
Fact. Set
Recommend. Setting
00
FACT MENU
0 - 1
0
Leave default set 0
01
PRESET PX
*
See note page 32
0 - 1
1
02
POWER MANAGE
0 - 7
0
03
VERT POS
*
See note page 32
0 - 30
15
04
HORZ POS
*
See note page 32
0 - 45
34
05
BAND/AFC
0 - 7
0
06
MIN VOLUME
0 - 63
0
07
MAX VOLUME
0 - 63
63
08
AC ON
0 - 1
0
9
KEY DEFEAT
0 - 1
0
10
STRT CH/VOL
0 - 255
255
11
HOSPITAL MODE
0 - 2
0
Leave default set 0
12
CHAN LOCK
0 - 1
0
13
GHOST CH.
0 - 1
0
14
SCAN MODE
0 - 3
0
Leave default set 0
15
TEXT MODE
0 - 1
1
16
SLEEP TIMER
0 - 1
0
17
ALARM
0 - 1
0
18
CH. OVER RIDE
0 - 1
1
19
OLD OCV
0 - 1
0
Set to 1 for Spectramate Systems
20
CAPTION LOCK
0 - 1
0
21
FUNCTION PRE
0 - 1
0
22
FEATURE LEVEL
0 - 1
1
Leave default set 1
23
NTSC SCANCARD
0 - 1
1
24
STRT CH IN SM
0 - 1
0
25
V-CHIP 1
0 - 1
1
26
MAX BLOCK HRS
0 - 99
12
27
STRT AUX SRCE
0 - 6
4