Page 8 of 24
Zenith Autoboil - Installation & Operating Instructions - 804545NZ - 03.17 v1.00
FILTER FLUSH
FILTERED
Fig.2
Depress
Inlet water
temp
15°C
10°C
3.0 Litre models
16 min
17 min
5.0 Litre models
16 min
17 min
7.5 Litre models
23 min
24 min
3)
Turn on the mains water. Allow at least 5 litres of water to flush
through the filter. Make sure there is water flowing from the
vent outlet (i.e. the valve setting is correct). Water should not
flow into the tank.
4)
Once the filter flush is complete, rotate the valve 180
⁰
(either
way) to the “
FILTERED
” position (fig 2). Replace the access
plug.
5)
Open the tap (push the lever backwards) into the locked open
position (fig 2) and allow the tank to fill until water flows from
the tap outlet.
6)
Once the water is available from the tap, turn off the mains
water and close the tap outlet.
7)
Turn on the power to the unit (water must be in the tank).
8)
Touch the white circle next to the left of the
[Tick] to
“Continue”
For screen operation, see the section on “Menu Operation”.
9)
Boiling Calibration will commence. It will take several minutes
for the water to boil.
Calibrating Completed
10)
When it completes (as prompted), turn on the mains water
supply.
11)
Select
to
Continue
12)
The home screen will be shown (see section 2.1).
13)
The tank will fill and heat. It will take the initial times shown in
the table to reach the final state.
Installation Procedures