End of life disposal

In order to help preserve our environment we ask that you 

dispose of this product correctly. Please contact your local city 

council for collection centre details.

Cleaning

Cleaning Case

Do not use strong, corrosive, spray or abrasive cleaners. Clean 

the case with a soft cloth or sponge and mild soapy water.

Dispose of the filter cartridge responsibly.

Use only Zenith Filter in this product to ensure effective filtration 

and operation.  Replacement filter cartridges can be obtained 

through plumbing suppliers or directly from Zenith.

Filter replacement instructions are included with the filter 

cartridge spare part kits.

Filter Replacement

Summary of Contents for Autoboil 3

Page 1: ...3 Litre White 303651 Zenith Autoboil 3 Litre Stainless Steel 305652 Zenith Autoboil 5 Litre White 305651 Zenith Autoboil 5 Litre Stainless Steel 307652 Zenith Autoboil 7 5 Litre White 307651 Zenith Au...

Page 2: ...ons including children with reduced physical sensory or mental capabilities or lack of expe rience and knowledge unless they have been given supervision or instruction concerning use of the appliance...

Page 3: ...ances without first isolating the heater from the power supply Do not use strong corrosive or abrasive cleaners to clean the case of the heater Frost protection If this heater is located where ambient...

Page 4: ...sed plumbing and or electrical connections Concealed connections are preferred for superior appearance Step 1 Positioning Position the heater so the tap will drain on to a draining board or drip tray...

Page 5: ...t the operation of the heater It is recommended that the heater be installed with a stop cock which allows it to be isolated from the mains supply for servicing Water pressure requirements Minimum 70...

Page 6: ...gh the rear access opening to the green terminal block on the PCB Check that the earth is connected through the PCB to the chassis with an ohm meter Warning Do not connect both options It is essential...

Page 7: ...ck nut Step 6 Installing Filter NOTE For safe operation the filter cartridge should be replaced every 6 12 months or earlier if you notice a persistent reduction in water pressure from the appliance o...

Page 8: ...the tap push the lever backwards into the locked open position fig 2 and allow the tank to fill until water flows from the tap outlet 6 Once the water is available from the tap turn off the mains wat...

Page 9: ...Understanding Icons and Buttons Move to the next item able to be highlighted Move to the previous item able to be highlighted Confirm menu selection Move to the previous menu Perform one of 3 functio...

Page 10: ...the sleep mode settings menu Filter Indication Days remaining of filter life Shown red filter needs replacement Sleep Mode Indication Unit will enter sleep mode at the time shown Unit will enter sleep...

Page 11: ...age 11 of 24 3 Settings Menu Select on the home screen to navigate to the main menu Choose Settings and select Choose an option and select 2 3 Sleep Override Mode Awake time remaining Unit will return...

Page 12: ...re quire boiling calibration to prevent excessive steam release or high energy usage see section 4 2 3 3 Settings Sleep Modes From the settings menu choose Sleep Modes and select Choose Sleep Trigger...

Page 13: ...ultaneously Adjust on off timer settings for the 2 weekend days simultane ously Adjust on off timer settings for the 7 days separately Weekdays Weekends Individual Days 3 3 3 Timer Settings Individual...

Page 14: ...the filter shown on this menu and on the home screen are based on these 2 parameters This action will reset the filter usage counter A re minder is shown to flush the new filter before doing this see...

Page 15: ...on environment may have changed requiring recalibration of the boiling point Incorrect boiling calibration points may cause excessive steam vent releases or increased energy usage Boiling calibration...

Page 16: ...e install menu choose Product 5 2 Info Current Fault From the info menu choose Current Fault 6 Service Menu Note The service menu is used by technicians only for diagnostic purposes Menu Operation 5 I...

Page 17: ...Zenith Autoboil Installation Operating Instructions 804545NZ 03 17 v1 00 Page 17 of 24 Wall Mounting Template Dimensions ROG QOHW 9HQW WHUQDO 3OXPELQJ OHFWULFDO LULQJ QWHUQDO 3OXPELQJ 3RVLWLRQLQJ SLQ...

Page 18: ...3118NZ Elbow Stem 1 4 19 90100NZ Grommet Cistern to Tank 20 94458NZ Overload 21 94459NZ Side release plug 22 94460NZ Seal transfer tube Item Kit Number Description 23 94483NZ Metering Tube 1 5 3 Ltr 9...

Page 19: ...Zenith Autoboil Installation Operating Instructions 804545NZ 03 17 v1 00 Page 19 of 24 Exploded View Diagram...

Page 20: ...on Water isolating valve turned off Blocked filter blocked meter tube blocked strainer jammed ball valve assembly Check filter flush valve position see Step 7 page 8 Check filter is inserted correctly...

Page 21: ...notice a persistent reduction in water pressure from the appliance or an unpleasant taste or odour in the water To Replace Filter Turn the filter anti clockwise fig 1 and pull the cartridge down fig...

Page 22: ...eaning Cleaning Case Do not use strong corrosive spray or abrasive cleaners Clean the case with a soft cloth or sponge and mild soapy water Dispose of the filter cartridge responsibly Use only Zenith...

Page 23: ...Zenith Autoboil Installation Operating Instructions 804545NZ 03 17 v1 00 Page 23 of 24 NOTES...

Page 24: ...one of continuous product improvement changes to specifications may be made without prior notice Images in this booklet have been modified and may not be true representations of the finished goods Th...

Reviews: