Gas and electrical connections

THE MANUFACTURER DOES NOT BEAR ANY 

RESPONSIBILITY FOR POSSIBLE DAMAGED 

CAUSED BY NON- OBSERVANCE OF STANDARDS 

AND REGULATIONS IN FORCE AS WELL AS HOB 

CONNECTION EXECUTED BY NOT AUTHORISED 

PERSON.

REMARK: Connection of the hob both to electrical and 

gas 

fi

 tting can be executed by quali

fi

 ed  authorised 

installer only.

Before connecting the hob to the electrical and gas 

fi

 tting check the information on the nameplate and 

herewith manual.

Before installing make sure that the local distribution 

 

conditions (the type of gas, its pressure) and the 

appliance adjustment are compliant.
The conditions of gas adjustment of the appliance are 

 

indicated on the nameplate.
The appliance is not connected to the fumes conduits. 

 

It should be installed and connected according to 

the binding installation regulations. The appropriate 

requirements concerning ventilation should be taken into 

consideration.
The 

fl

 exible gas connection shall be assembled such 

 

way, that it is not in contact with the furniture parts in 

move (i.e. drawer) and it shall be not located in the are 

with not enough space.
The wiring supplying the power to the hob shall be 

 

secured with properly selected safety device.
Upon installing the hob, the installer is obliged to check 

 

the tightness of the gas 

fi

 tting.

REMARK: The installer is obliged to 

fi

 ll in the warranty 

card, which is the basis for the warranty and guaranty.

Replacing the nozzles for the other  
type of gas 

(Fig. B)

ATTENTION: The hob nozzles replacing can be 

executed only by an authorised quali

fi

 ed installer.

The gas hob is the nozzles are defaulted for 2E (G20) gas. 

The other kinds of gas are:

BURNER

GAS

PRESSURE

NOZZLE 

MARKING

THERMAL 

CAPACITY

WOK

2E (G20)

3B/P (G30)

20 mbar

37 mbar

1.36

0.86

3300 W

LARGE

2E (G20)

3B/P (G30)

20 mbar

37 mbar

1.18

0.72

2500 W

MEDIUM

2E (G20)

3B/P (G30)

20 mbar

37 mbar

0.92

0.58

1500 W

SMALL

2E (G20)

3B/P (G30)

20 mbar

37 mbar

0.75

0.49

1000 W

1

 Remove the cap and crown.

2

 Unscrew the nozzle using a special spanner.

3

 Replace the nozzle screwing the appropriate one 

according to the table.

After the nozzles exchange adjust the burners (see 

”FLAME ADJUSTMENT”.

Upon nozzles replacement glue an adequate label 

indicating the gas type near the end of shaft connecting 

the hob manifold.

Technical specifi cation

The technical parameters of the hob are indicated at the 

nameplate of the appliance.  
The hob is equipped with a shaft with threaded end of G1/2” 

diameter for connecting to gas supply 

fi

 tting. In case of 

connection to LPG cylinder (propane –butane) the ending 

of the 

fl

 exible hose 

 8 x 1mm is screwed on the threaded 

shaft end.
The gas hob is the 1st class appliance equipped with 

a connecting cord with protecting stand. It requires 

connection to the socket equipped with an earth pin.
the appliance meets the requirements of the standards in 

force.
The appliance is in conformance with the requirements of the 

following directives:

Appliances burning gaseous fuels – 90/396/EEC, 

 

93/68/EEC.

Low Voltage Devices (LVD) – 2006/95/EC.

 

Electromagnetic compatibility (EMC) – 2004/108/EC.

 

The product has been labelled with CE mark on the 

nameplate.

The appliance outline  

(Fig. D)

1

 Large burner 

Ø 100 mm 

2.5 kW

2

 Medium burner 

Ø 75 mm 

1.5 kW

3

 Small burner 

Ø 55 mm 

1.0 kW

4

 WOK burner 

Ø 130 mm 

3.3 kW

5

 Burner control knobs with electric ignition candle

6

 Burner grate

7

 Burner cap

8

 Burner crown

9

 Burner body

10

 Ignition candle

11

 Anti-gas 

fl

 ow security device

Flame adjusting 

(Fig. C)

1

 Switch on the burner and set the minimum 

fl

 ame   .

2

 Remove the ring knob from the spindle.

3

 Adjust the 

fl

 ame turning the screw inside the spindle with 

an appropriate screwdriver.

Summary of Contents for ZPG6014CP

Page 1: ...CP 10 13 HU HASZN LATI UTAS T S G zf z lap ZPG6074SP ZPG6085SP ZPG6114CP ZPG6125CP T pus 14 17 RO INSTRUC IUNI DE UTILIZARE Plita pe gaz Tip ZPG6074SP ZPG6085SP ZPG6114CP ZPG6125CP 18 21 RU T ZPG6074S...

Page 2: ...2 PG 004_v01 A PL D B C 5 5 4 2 1 3 2 2 6 3 7 8 9 10 11...

Page 3: ...przeszko lony personel Nieprawid owo wykonana naprawa mo e spowodowa powa ne zagro enie dla u ytkownika Dysze pokr t a ruszty stosuj tylko oryginalne dost pne w autoryzowanych punktach serwisowych W r...

Page 4: ...ej PALNIK GAZ CI NIENIE OZNACZENIE DYSZY OBCI ENIE CIEPLNE WOK 2E G20 3B P G30 20 mbar 37 mbar 1 36 0 86 3300W DU Y 2E G20 3B P G30 20 mbar 37 mbar 1 18 0 72 2500W REDNI 2E G20 3B P G30 20 mbar 37 mb...

Page 5: ...ej Do czyszczenia p yty szklanej nie u ywaj sprz tu do czyszczenia par Lekkie zanieczyszczenia nawil najpierw ciep wod a nast pnie za pomoc g bki przetrzyj do sucha Mocne zanieczyszczenia nawil najpie...

Page 6: ...6 PG 004_v01 A proud n vzduchu t sn n CZ D B C 5 5 4 2 1 3 2 2 6 3 7 8 9 10 11...

Page 7: ...em innosti spot ebi e zah vaj Nedot kejte se hork ch st spot ebi e Hroz nebezpe pop len P ed i t n m nechejte spot ebi vystydnout Nenech vejte spot ebi se zap len mi ho ky bez dozoru zejm na b hem sma...

Page 8: ...deny na v robn m t tku Varn deska je vybavena p vodem se z vitem o pr m ru G1 2 slou c mu k p ipojen k plynov instalaci V p pad zapojen na plynovou l hev propan butan se na p vod roubuje koncovka na h...

Page 9: ...v dy hrnec p ikr vejte pokli kou V p pad p eru en dod vky elekt iny m ete ho ky zapalovat z palkami Nestavte jednu n dobu na dva ho ky sou asn Pou vejte ist a such n doby a takov jejich v ka p edstavu...

Page 10: ...10 PG 004_v01 A pr denie vzduchu tesnenie SK D B C 5 5 4 2 1 3 2 2 6 3 7 8 9 10 11...

Page 11: ...r vne vykonan oprava m e by pr inou v neho ohrozenia pre pou vate a Pou vajte iba origin lne dostupn v autorizovan ch servisoch d zy oto n prep na e a ro ty V pr pade poruchy sa obr te na pecializovan...

Page 12: ...3300W VE K 2E G20 3B P G30 20 mbar 37 mbar 1 18 0 72 2500W STREDN 2E G20 3B P G30 20 mbar 37 mbar 0 92 0 58 1500W MAL 2E G20 3B P G30 20 mbar 37 mbar 0 75 0 49 1000W 1 Sn mte z hor ka klob ik a korunk...

Page 13: ...ra ujte nane sen m na zne isten miesto mal ho mno stva peci lneho pr pravku na istenie sklokeramick ch dosiek alebo bieleho vinn ho octu a potom ho zotrite suchou handri kou Sladkosti roztaven hlin k...

Page 14: ...14 PG 004_v01 A l g ramlat t m t s HU D B C 5 5 4 2 1 3 2 2 6 3 7 8 9 10 11...

Page 15: ...elenthet Kiz r lag csak az eredeti m rkaszerv zben kaphat f v k kat szab lyz gombokat r csokat haszn lja Ha a k sz l k m k d s ben zavar l pne fel azt javasol juk hogy egy m rkaszerv zhez forduljon Bi...

Page 16: ...MIKUS TELJES TM NY WOK 2E G20 3B P G30 20 mbar 37 mbar 1 36 0 86 3300W NAGY 2E G20 3B P G30 20 mbar 37 mbar 1 18 0 72 2500W K ZEPES 2E G20 3B P G30 20 mbar 37 mbar 0 92 0 58 1500W KICSI 2E G20 3B P G3...

Page 17: ...a el ut na bl tse s sz razra t r lje Ellen rizze hogy az g korona ny l sai nincsenek e elt m dve valamint a fedelek megfelel en maranak e az g k n Az veglapok tiszt t sa Az veglapokat ne tiszt tsa g z...

Page 18: ...18 PG 004_v01 A circula ia aerului garnitur RO D B C 5 5 4 2 1 3 2 2 6 3 7 8 9 10 11...

Page 19: ...t fi efectuate numai de c tre o persoan calificat Repara iile efectuate n mod necorespunz tor pot pune serios n pericol via a utili zatorului Folosi i numai jicloare butoane i gr tare originale ce pot...

Page 20: ...iberat garan ia Schimbarea jiclorului pentru alt tip de gaz Desen B ATEN IE Schimbarea jiclorului poate fi efectuat numai de c tre un instalator autorizat care posed calificarea necesar Din fabric jic...

Page 21: ...diametru Nu repara i niciodat singur aparatul Cur are i p strare Re ine i c trebuie s p stra i mereu plita curat Cur a i gr tarele capacele i coroanele arz toarelor folo sind ap cald cu pu in deterge...

Page 22: ...22 PG 004_v01 A 2 5 0 5 510 473 50 100 100 553 600 50 76 RU 50 D B C 5 5 4 2 1 3 2 2 6 3 7 8 9 10 11...

Page 23: ...23 PG 004_v01 RU Zelmer Zelmer A 1 2 3 4...

Page 24: ...2E G20 3B P G30 20 37 1 36 0 86 3300W 2E G20 3B P G30 20 37 1 18 0 72 2500W 2E G20 3B P G30 20 37 0 92 0 58 1500W 2E G20 3B P G30 20 37 0 75 0 49 1000W 1 2 3 G1 2 8 x 1 I 90 396 EEC 93 68 EEC LVD 2006...

Page 25: ...25 PG 004_v01 D 1 100 2 5 2 75 1 5 3 55 1 0 4 130 3 3 5 6 7 8 9 10 11 C 1 2 3 3B P G30 10 15 1 1 130 mm 240 260 mm 100 180 260 mm 75 120 220 mm 55 80 160 mm 2 3 PE...

Page 26: ...26 PG 004_v01 A 2 5 0 5 510 473 50 100 100 553 600 50 76 50 BG D B C 5 5 4 2 1 3 2 2 6 3 7 8 9 10 11...

Page 27: ...27 PG 004_v01 BG Zelmer Zelmer A 1 2 3 4 4...

Page 28: ...bar 37 mbar 1 36 0 86 3300W 2E G20 3B P G30 20 mbar 37 mbar 1 18 0 72 2500W 2E G20 3B P G30 20 mbar 37 mbar 0 92 0 58 1500W 2E G20 3B P G30 20 mbar 37 mbar 0 75 0 49 1000W 1 2 3 G1 2 8 x 1 90 396 EEC...

Page 29: ...29 PG 004_v01 D 1 100 mm 2 5 kW 2 75 mm 1 5 kW 3 55 mm 1 0 kW 4 130 mm 3 3 kW 5 6 7 8 9 10 11 C 1 2 3 3B P G30 10 15 1 1 130 mm 240 260 mm 100 200 220 REDNI 75 160 180 55 100 140 2 3...

Page 30: ...30 PG 004_v01 A 2 5 0 5 510 473 50 100 100 553 600 50 76 50 UA D B C 5 5 4 2 1 3 2 2 6 3 7 8 9 10 11...

Page 31: ...31 PG 004_v01 UA Zelmer Zelmer A 1 2 3 4 4...

Page 32: ...bar 37 mbar 1 36 0 86 3300W 2E G20 3B P G30 20 mbar 37 mbar 1 18 0 72 2500W 2E G20 3B P G30 20 mbar 37 mbar 0 92 0 58 1500W 2E G20 3B P G30 20 mbar 37 mbar 0 75 0 49 1000W 1 2 3 G1 2 8 x 1 I 90 396 EE...

Page 33: ...33 PG 004_v01 D 1 100 2 5 kW 2 75 1 5 kW 3 55 1 0 kW 3 130 3 3 kW 4 5 6 7 8 9 10 C 1 2 3 3B P G30 10 15 1 i 1 130 mm 240 260 mm 100 180 260 mm 75 120 220 mm 55 80 160 mm 2 3 a a a a a PE...

Page 34: ...34 PG 004_v01 26663 19848 5 40 1 15150...

Page 35: ...35 PG 004_v01 A airflow seal EN D B C 5 5 4 2 1 3 2 2 6 3 7 8 9 10 11...

Page 36: ...agent or similarly qualified person in order to avoid a hazard It can be refurbished by qualified staff only Improper refurbishment can cause serious hazard for the user Use only genuine nozzles grate...

Page 37: ...WOK 2E G20 3B P G30 20 mbar 37 mbar 1 36 0 86 3300W LARGE 2E G20 3B P G30 20 mbar 37 mbar 1 18 0 72 2500W MEDIUM 2E G20 3B P G30 20 mbar 37 mbar 0 92 0 58 1500W SMALL 2E G20 3B P G30 20 mbar 37 mbar 0...

Page 38: ...hall be washed with warm water and detergent then rinse and dry all elements All outlets in the hob burner crown must be permeable and the caps shall be well positioned on them Cleaning of the glass p...

Page 39: ...PG 004_v01...

Page 40: ...PG 004_v01...

Reviews: