23
PG-005_v01
The earthing wire must be connected to the
terminal marked with the symbol
. The
electrical installation supplying the hob should
be protected with a properly selected safety
device and, in addition, it should be equipped
with a suitable switch enabling the current to
be cut off in an emergency situation.
Make sure that the mains voltage corresponds to the
●
voltage on the rating label located on the appliance
casing.
The hob is designed to be connected to a 230 V 50 Hz
●
AC electricity supply and should be connected to a mains
socket equipped with a properly connected earthing
contact.
If the electrical installation is damaged, connecting the
●
hob to the socket without an earthing contact will create
the risk of electric shock.
The installer is obliged to
fi
ll in the warranty
card, which is the basis for warranty claims.
Changing the nozzles for diff erent
type of gas
(Fig. B)
Nozzles can be changed only by a certi
fi
ed
installation technician.
The gas hob is equipped with nozzles adapted for use with
2E (G20) gas.
Type of gas and gas pressure, as well as thermal power and
designation of nozzles for particular burners are shown in the
table below:
BURNER
GAS
PRESSURE
NOZZLE
MARKING
THERMAL
CAPACITY
LARGE
2E (G20)
3B/P (G30)
20 mbar
37 mbar
1.18
0.72
2500 W
MEDIUM
2E (G20)
3B/P (G30)
20 mbar
37 mbar
0.92
0.58
1500 W
SMALL
2E (G20)
3B/P (G30)
20 mbar
37 mbar
0.75
0.49
1000 W
1
Remove the burner cap and crown.
2
Unscrew the nozzle using a special spanner.
3
Replace the nozzle with that for a new type of gas
according to the table.
After changing the nozzles, adjust the burners (see
“FLAME ADJUSTMENT”).
After changing the nozzles af
fi
x an appropriate
label showing the new type of gas at the hob
connecting pipe.
Technical Parameters
The technical parameters are indicated on the rating label.
The hob is equipped with a threaded connecting pipe
G1/2’’ used for connecting to the gas mains. In the case of
connecting the hob to liquid gas (propane-butane) tanks the
fi
tting for
∅
8 x 1 mm hose must
fi
rst be screwed onto the
connecting pipe.
The gas hob is a class 1 appliance equipped with a power
cord with an earthing wire. It must be connected to the mains
socket equipped with an earthed pin.
The appliance satis
fi
es the requirements of relevant
standards.
The appliance complies with the following directives:
Appliances burning gaseous fuels (GAD) – 90/396/EEC,
–
93/68/EEC.
Low Voltage Directive (LVD) – 2006/95/EC.
–
Electromagnetic Compatibility (EMC) – 2004/108/EC.
–
The product is marked with the CE symbol on the rating label.
Appliance elements
(Fig. D)
1
Large burner
Ø 100 mm
2.5 kW
2
Medium burner
Ø 75 mm
1.5 kW
3
Small burner
Ø 55 mm
1.0 kW
4
Burner knobs with ignition switch
5
Pan support
6
Burner cap
7
Burner crown
8
Burner base
9
Ignitor
10
Flame failure safety device
Flame adjustment
(Fig. C)
Flame adjustment should be performed by
a certi
fi
ed installation technician.
1
Light the burner and set it to the minimum
fl
ame .
2
Remove the knob from the shaft.
3
Use a special screwdriver and adjust the
fl
ame by turning
the screw inside the shaft. As a result you will obtain a small,
uniform
fl
ame around the burner.
In the case of 3B/P (G30) gas the screw must be fully
screwed in (clockwise).
4
Replace the knob
Make sure that when the knob is turned rapidly from
maximum to minimum , the
fl
ame does not go out.
5
Turn off the burner by turning the knob to position .
Summary of Contents for ZPG6004SZ
Page 2: ...D 2 PG 005_v01 A PL 6 7 8 10 9 B C 4 4 2 3 1 5 ...
Page 8: ...D 8 PG 005_v01 A CZ B C proudění vzduchu těsnění 6 7 8 10 9 4 4 2 3 1 5 ...
Page 14: ...D 14 PG 005_v01 A SK B C prúdenie vzduchu tesnenie 6 7 8 10 9 4 4 2 3 1 5 ...
Page 20: ...D 20 PG 005_v01 A EN B C airflow seal 6 7 8 10 9 4 4 2 3 1 5 ...
Page 26: ...PG 005_v01 ...
Page 27: ...PG 005_v01 ...
Page 28: ...PG 005_v01 ...