background image

 

15 

- remove the seven screws (100) holding the air guide 

 

2.4  Convection motor fan removal 

- remove the six screws (100) securing the back housing (39) 
- remove the four screws (100) with the four washers 

Ø4.4 which hold the convection element housing (62)  

  to the rear wall (inside the cavity) 
- remove the convection fan (64) with tubular spanner size 10 (caution: left-hand thread) 
- remove the four screws (100) which hold the insulation support (37), lift the support off the latches 
- remove the three screws (104) inside the cavity securing the convection motor (66) 

 

2.5  Heaters removal 

- remove the seven screws (100) holding the top housing (35) 
- remove the two screws (100) holding the heating bracket (73) 
- remove the two nuts with tubular spanner size 7 holding the top heating element assembly (72) 
- remove the two nuts with tubular spanner size 7 holding the convection heating element (63) 
- remove the six screws (100) securing the bottom housing (59) 
- remove the four screws (100) and remove the bottom heater (61) 

 

2.6  Cavity light removal 

- remove the top, back and sides housings 
- release the latches securing the lamp (26) and remove it 

 

3. LIST OF TOOLS AND MEASURING INSTRUMENTS

 

– 

Set of screwdrivers  

– 

Electric soldering tool  

– 

Wire insulation stripper  

– 

Wattmeter, Class 0,5, range 100/200/300V, 10/20A  

– 

Ohmmeter Tester, Class 0,5 500V DC  

– 

Autotransformer 

4. NOTES 

4.1  The facility does not ship individual parts. 
4.2  The facility reserves the right to change the shape of a part to improve the quality and function-

ality of the product.

 

5. TROUBLE SHOOTING 

Item  Condition 

Cause  

Remedy 

The oven does not 
work. 

1.3.

 

Faulty thermostat. 

Replace.  

1.4.

 

Faulty power board. 

Replace. 

2

 

The oven does not 
heat.

 

2.5.

 

Faulty Upper heater. 

Replace. 

2.6.

 

Faulty grill heater. 

Replace. 

2.7.

 

Faulty bottom heater. 

Replace. 

2.8.

 

Faulty convection heater. 

Replace. 

 

6. COMPONENTS TEST PROCEDURE 

 

COMPONENTS 

TEST PROCEDURE 

RESULTS 

Cooling Motor 
(wire leads removed ) 

Measure the resistance 
(ohm-meter scale: R×100) 

Normal: Less than 250Ω, 
Abnormal:∞ or several Ω 

Convection Motor 
(wire leads removed ) 
 

Measure the resistance 
(ohm-meter scale: R×100) 

Normal: Less than 250Ω, 
Abnormal:∞ or several Ω 

Top Heater 
(wire leads removed ) 
 

Measure the resistance 
(ohm-meter scale: R×100) 

Normal: Less than 70Ω, 
Abnormal:∞ or several Ω 

Summary of Contents for ZME 8061ED

Page 1: ...Hz Moc wyj ciowa Nominal power 3100 W Moc grza ki g rnej Top heater power 950 W Moc grza ki dolnej Bottom heater power 1100W Moc pobierana konwekcji Convection heater power 2200 W Moc pobierana grill...

Page 2: ...nik ch odzenia M2 silnik termo obiegu Main PCB locator chart M1 cooling fan motor M2 convection fan motor C Cz Br Cz C B Br CzCz N CzCz CzCz Oznaczenia na rysunku B bia y white Cz czerwony red N niebi...

Page 3: ...3 RYSUNEK W ROZ O ENIU NA CZ CI EXPLODED DRAWING...

Page 4: ...4...

Page 5: ...5...

Page 6: ...E805005 5900215992655 1 6 DYSTANS R CZKI ZME805 DOOR HANDLE BRACKET 0ZME805006 5900215992662 2 7 PODK ADKA R CZKI ZME805 DOOR HANDLE GASKET 0ZME805007 5900215992679 2 0ZME806007 5900215992686 8 BLOKAD...

Page 7: ...92907 1 26 LAMPA KPL ZME LAMP 0ZME805026 5900215992914 1 27 POKRYWA KANA U SPALIN FLUE COVER 0ZME805027 5900215992921 1 28 PODSTAWA P YTKI ZASILANIA POWER BOARD BRACKET 0ZME805028 5900215992938 1 29 P...

Page 8: ...5050 5900215993126 1 51 PANEL KATALITYCZNY CATALYTIC 0ZME805051 5900215993133 2 Add equipment 52 PROWADNICA ZME SLIDE 0ZME805052 5900215993140 2 Left and right slide 53 RUSZT ZME BAKING RACK 0ZME80505...

Page 9: ...ZYBY ZME DOOR SEAL 0ZME805074 5900215993324 1 75 POKRYWA G RNA DRZWICZEK ZME DOOR TOP COVER 0ZME805075 5900215993331 1 76 SZYBA WEWN TRZNA ZME DOOR INNER GLASS 0ZME805076 5900215993348 1 77 SZYBA RODK...

Page 10: ...handlowa commercial part 87 101 WKR T STO KOWY TWFZ 3x6 SCREW 3 l 8 cz handlowa commercial part 16 102 WKR T M5 l 33 SCREW M5 l 33 cz handlowa commercial part 2 103 WKR T M5 l 10 SCREW M5 l 10 cz hand...

Page 11: ...ki 04 05 odkr ci dwa wkr ty 103 a nast pnie zdemon towa zawiasy kpl 02 odkr ci dwa wkr ty 102 zdemontowa r czk 03 2 2 Panel sterowania p ytka PCB p ytka zasilania wykr ci cztery wkr ty 100 mocuj ce ty...

Page 12: ...mocuj cych pokryw doln 59 odkr ci cztery wkr ty 100 mocuj ce wspornik grza ki dolnej wyj grza k doln 61 2 6 Lampa zdemontowa obudowy zdj izolacj komory zwolni zaczepy mocuj ce opraw lampy 26 i wyj op...

Page 13: ...na grza ka od czone konektory Pomiar rezystancji ohm R 100 Prawid owo 70 Nieprawid owo lub kilka Grza ka grilla od czone konektory Pomiar rezystancji ohm R 100 Prawid owo 70 Nieprawid owo lub kilka Do...

Page 14: ...the hinge gaskets 04 05 remove two screw 103 remove the hinge assembly 02 remove the two screws 102 and the handle 03 2 2 Control panel and LED board control PCB and power board removal remove the fo...

Page 15: ...emove the top back and sides housings release the latches securing the lamp 26 and remove it 3 LIST OF TOOLS AND MEASURING INSTRUMENTS Set of screwdrivers Electric soldering tool Wire insulation strip...

Page 16: ...everal Bottom Heater wire leads removed Measure the resistance ohm meter scale R 100 Normal Less than 70 Abnormal or several Convection Heater wire leads removed Measure the resistance ohm meter scale...