background image

OPMI

®

 Pentero

®

Software Release 2.2

Brief instructions

G-30-1702-en

Issue2.0

Printed on 17. 03. 2008

Summary of Contents for OPMI Pentero

Page 1: ...OPMI Pentero Software Release 2 2 Brief instructions G 30 1702 en Issue2 0 Printed on 17 03 2008...

Page 2: ...tation coobservation equipment Page 16 Adjusting the tubes and eyepieces Page 17 Setting the eyepieces compensation for ametropia Page 18 Setting the adjustment speeds of focus and zoom Page 19 OR lay...

Page 3: ...l draw your attention to safety as pects and useful tips These symbols are explained in the following Warning The warning triangle indicates potential sources of danger which may constitute a risk of...

Page 4: ...he correct use of the system is absolutely vital for safe operation Therefore please thoroughly familiarize yourself with the content of user manual G 30 1458 before starting up the system Before star...

Page 5: ...anced Before starting make sure to read the chapter Preparations for use of the user manual Press the brake release buttons AB to unlock all magnetic brakes Keep the brake release buttons AB pressed a...

Page 6: ...all directions with a minimum of effort Right hand pedal 2 is pressed down hard until it snaps in Reliable and precise straight ahead movement also over low thresh olds elevator Press this pedal until...

Page 7: ...G 30 1702 en OPMI Pentero Software Release 2 2 Issue 2 0 Printed on 17 03 2008 7 3 4 5 6 5 6...

Page 8: ...tation movements of the surgical microscope DRAPE Hier luftdicht abschlie en Make airtight here Fermer herm tiquement ici Cerrar herm licamente aqui Effective range of drape vacuum system Sterile area...

Page 9: ...al ancing procedure and the subsequent test must not be performed above the patient and only at a safe distance from other persons and devices Hold the microscope tightly at both handgrips Unlock the...

Page 10: ...ro Software Release 2 2 Issue 2 0 Printed on 17 03 2008 Central user interface touchscreen Note For detailed information on the submenus and their configuration please see user manual G 30 1458 MENU U...

Page 11: ...deo signal in full display size PAT FILES Use the Patient Files menu to save edit and manage patient data videos and images USER The USER menu permits you to save user specific settings for several di...

Page 12: ...pacity Int Ext G 30 1458 STAND MENU Intensity Start Value Light On Off OPMI LIGHT Light Intensity Control On Off Low Medium AUDIO VIDEO High Remaining lamp lifetime LIGHT Brightness Speed 30 12 04 17...

Page 13: ...ever for changing the lamp moves out Pull out the lever as far as it will go without using force If the lever has not been properly pulled the lamp will not be changed Pull the lever again to make the...

Page 14: ...ever 1 and adjust the mounting bar or the handgrip only to the position required Choose a position of the handgrips which is most convenient for the surgical procedure to be performed Make sure that t...

Page 15: ...ring the handgrip buttons Press CONFIG to configure both handgrips For separate programming of the left or right handgrip press the LEFT or RIGHT button respectively The buttons are only displayed if...

Page 16: ...g the programmable buttons A B C D Press the button A B C D to which you would like to assign a dif ferent function Then press the relevant function in selection menu 1 to assign it to the selected bu...

Page 17: ...r 3 and firmly tighten secur ing screw 7 Insert widefield eyepieces 1 as far as they will go in the mounts pro vided on the binocular tube Attach binocular coobservation tube 5 to the microscope body...

Page 18: ...ring 1 onto accessory module 3 and firmly tighten it The type of coobservation lateral image exit ports left right or opposite image exit ports face to face can be configured at the touchscreen CONFI...

Page 19: ...one 3 Eyecup Adjust the eyecups in such a way that the entire field of view can be seen 4 Diopter setting ring The eyepieces provide compensation for ametropia Eyeglass wearers using their glasses dur...

Page 20: ...eticle Eyepieces with reticle Remove the binocular tube and the eyepieces from the microscope body and point them at a distant ob ject i e use them like a pair of bi noculars The image of the object i...

Page 21: ...SYSTEM INFO TELEPHONE FLUORESCENCE Autofocus Automatic Micromanipulator Focus Stop Focus Start Value MENU PAT FILES ZOOM DIAPHRAGM TUBE On Off On Off On Off On Off 50 300 mm Focus Zoom Link Focusing A...

Page 22: ...port Insert a new blank data carrier in the CD DVD drive or plug a USB stick into the port on the touchscreen 8 9 Export in the DICOM format See DICOM option 10 Save images anonymously Enables anonymo...

Page 23: ...LOAD SAVE BACK SORT Benninger Ralph Bachmann E Busch W ADD DELETE EDIT LIST 30 12 04 17 56 User XXXXXXXX Patient Benninger Ralph Recorder Capacity Int Ext PAT FILES MENU USER CONFIG PATIENT IMAGES VID...

Page 24: ...xternal monitor Suitable for devices capable of processing VBS signals or if video sig nals have to be transmitted over relatively long distances 2 Video signal output port for an external monitor Y C...

Page 25: ...G 30 1702 en OPMI Pentero Software Release 2 2 Issue 2 0 Printed on 17 03 2008 25 BNC 1 Y C 2...

Page 26: ...of the magnetic brakes are blocked Switch off power switch 4 As soon as the blue screen appears approx 10 sec switch the system back on The OPMI functions zoom focus light and magnetic brakes are ava...

Page 27: ...27 7 Failure of control functions Set emergency switch 7 to the emergency mode po sition 2 Zoom and focus must then be operated man ually 2 3 Hold the microscope on its body not on the handgrips and...

Page 28: ...lever the lamp is not changed Pull the lever again to make the lamp snap in Close the flap again Order a new xenon lamp Cat No 2 is shown on the lamp module Note Only change the used lamp if replacem...

Page 29: ...G 30 1702 en OPMI Pentero Software Release 2 2 Issue 2 0 Printed on 17 03 2008 29 1 2 3...

Page 30: ...of the zoom drive In the event of a failure of the zoom drive e g zoom drive moves con stantly into an end position Set the mode selector switch on the connection panel to emergency operation This ens...

Page 31: ...he focusing drive In the event of a malfunction of the focusing drive e g focusing drive moves constantly into an end position Set the mode selector switch on the connection panel to emergency operati...

Page 32: ...o your entries you can still con tinue to operate the OPMI Pentero with the current settings To restore the touchscreen function proceed as follows Switch the suspension system off and back on again a...

Page 33: ...alized In the event of power failure magnetic brakes are locked you can man ually position the arm of the suspension system with the microscope by overcoming the locking effect of the brakes Error mes...

Page 34: ...switch 3 has been switched on Remove magnetic plate 1 which covers emergency mode switch 2 Set switch 2 from position 1 to position 2 emergency mode The microscope and suspension system functions have...

Page 35: ...nctions are still available Motorized focusing via handgrip or foot control panel Motorized magnification setting via handgrip or foot control panel Focus and zoom speeds correspond to the speeds set...

Page 36: ...008 CE label The system meets the essential requirements stipulated in Annex I to the 93 42 EEC Directive governing medical devices The system is labeled with Subject to change Subject to changes in d...

Page 37: ...ions failure of 34 D Data export to CD DVD USB DICOM 22 Diopter scale 19 Diopter setting ring 19 Drapes attaching 8 E Emergency instructions overview 28 Emergency mode 34 Emergency what to do 26 Error...

Page 38: ...b 19 Positioning at operating table system 6 R Risk of phototoxic injuries 12 S Subject to change 36 Switching on the system 4 System positioning at operating table 6 T Touchscreen 10 Tube mounting of...

Page 39: ...G 30 1702 en OPMI Pentero Software Release 2 2 Issue 2 0 Printed on 17 03 2008 39...

Page 40: ...rl Zeiss Surgical GmbH A Carl Zeiss Meditec Company 73446 Oberkochen Germany Fax 49 0 7364 20 48 23 Email surgical meditec zeiss com Internet www meditec zeiss com G 30 1702 en Printed in Germany CG S...