2.2 Safety information regarding operation of the
device
The device may only be operated by trained personnel. These personnel members
must be informed of the possible dangers involved in working with the device
and in the device's relevant area of application. The MCS 600 is a precision inst-
rument which can be impaired in its performance or damaged if handled incor-
rectly.
The power plug must be plugged into a grounded socket. The grounding effect
must not be made ineffective through the use of an extension cable which does
not have a protective ground wire. If the protective measures are found to be
ineffective, the device must be switched off and safeguarded against inadvertent
use. Contact ZEISS customer service to repair the device.
Before putting the device into service, check whether the available line voltage
is suitable for the device. Always unplug the device before opening it and before
changing the fuses! Only fuses which comply with the requirements provided in
the specifications may be used. Using makeshift fuses or short-circuiting the fuse
holders is not permitted. The device must be positioned in such a way that the
power plug can be reached at all times. The device can only be fully disconnected
from the power supply by unplugging the power plug.
The device must not be put into service if it is damaged or wet.
The warning signs and safety information on the device must not be removed
and must always be in a legible condition. Safety components must not be mo-
dified or removed. The device must be checked regularly to ensure that it is in
proper working condition.
Caution
UV radiation!
Never look directly into the measuring beam. The coherent UV beam
may lead to injury of the eye (e.g. conjunctivitis).
Caution
Hot surface warning
Warning
The connection requirements must be complied with!
The requirements set out in the "Connection requirements" section of
this user manual must be complied with in order to operate the device
system. Failure to comply with these requirements may result in device
faults or erroneous measurements.
Summary of Contents for MCS 600
Page 1: ...User Manual Carl Zeiss Spectroscopy GmbH MCS 600...
Page 14: ...14 MCS 600 User Manual System Overview MCS 600...
Page 22: ...22 MCS 600 User Manual MCS 600...
Page 30: ...30 MCS 600 User Manual MCS 600...
Page 32: ...32 MCS 600 User Manual MCS 600...
Page 36: ...36 MCS 600 User Manual MCS 600 1 3 4 5 6 2 Fig 17 BLX 600 SMA lamp replacement...
Page 40: ...40 MCS 600 User Manual MCS 600 1 3 4 5 6 2 Fig 20 BLX 600 CZ6 lamp replacement...
Page 44: ...44 MCS 600 User Manual MCS 600 1 3 4 5 6 2 Fig 23 BLX 606 lamp replacement...
Page 48: ...48 MCS 600 User Manual MCS 600 1 3 4 6 5 7 8 9 2 Fig 26 CLD 600 lamp replacement...
Page 52: ...52 MCS 600 User Manual MCS 600 1 3 4 5 6 2 Fig 29 CLH 600 lamp replacement...
Page 56: ...56 MCS 600 User Manual MCS 600 1 3 4 5 6 2 Fig 32 CLH 600 F lamp replacement...
Page 60: ...60 MCS 600 User Manual MCS 600 1 3 4 5 2 Fig 35 CLH 606 A bulb replacement...
Page 66: ...66 MCS 600 User Manual MCS 600 Network Connection MCS 600...
Page 68: ...68 MCS 600 User Manual Maintenance and Care MCS 600...