2.7.1 display on the unit

The ComfoAir can be operated and commissioned by 
means of a display. The display is a digital operating 
device  which is mounted on the ComfoAir.

select menu 

 up

OK 

 down

supply off 

 supply on 

 (led green) 

 (led green)

 comfort temperature 

Shown in display

  Ventilation setting absent
  Ventilation setting low
  Ventilation setting medium
  Ventilation setting high
  Menu symbol
  Malfunction code (flashes)
  Bypass  

Access to the menus

Sequence

Press

display

description

1

MENU

P2

Time delay

2

+

 ▼

(3 seconds)

P3

Press the buttons 

simultaneously.

3

s

P4

Temperatures

4

s

P5

Settings

5

s

P6

Settings

6

s

P7

Malfunction / Reset / 

Self-test

7

s

P8

0 - 10V Inputs

8

s

P9

Status

Example

 

Setting  the  MEDIUM  POSITION  of  the  supply  fan  to 
40%.

Sequence

Press

display

description

1

MENU

P2

Time delay

2

+

 ▼

(3 seconds)

P3

Press the buttons 

simultaneously.

3

OK

P30

Exhaust fan 

Position A

4

(6x)

P36

Select P36

5

OK

50

Current setting

6

▼ 

(10 x or press 

continuously)

40

Select 40

7

OK

P36

Value is 40

8

MENU

P3

9

MENU

1

Fan setting

 Some P menus (such as P1 and P9) can only 
be read.

Leaving Reading menu 

•   At action point 6 press "MENU" (instead of "OK").

  The display can not be used for setting the 

ventilation positions of the ComfoAir. The 
arrowkeys are only for setting the additional 
programmes.

2.7.2  CC Ease panel

The ComfoAir can be operated and commissioned 
by means of a CC Ease panel, which can be ordered 
separately. The CC (Comfort Control) Ease panel is 
a digital operating device which can be mounted on 
the wall in the living room and from there communi-
cates with the ComfoAir. 

Accessing the P menus

1.  Press and hold "

" and "

 "  for 2 seconds, 

simultaneously.

   - Wait until "P 2" appears on the display.

 

P menus P1, P2 and P9 can now be ac-
cessed

.

2.  Press

 

and hold "

 " and "

" for 2 seconds, 

simultaneously.

     - Wait until P menu ”P3" appears on the  

display.

 

P menus P3 to P8 can now be accessed

.

3.  Select the desired P menu, e.g. " 5 ", using " 

 

" or " 

 ".

1

A

2

3

X   X

X   X

1

A

2

3

X   X

X   X

1

A

2

3

X   X

X   X

1

A

2

3

X   X

X   X

1

A

2

3

X   X

X   X

OK

MENU

·

·

·

OK

MENU

·

·

·

OK

MENU

·

·

·

OK

MENU

·

·

·

OK

MENU

·

·

·

1

A

2

3

X   X

X   X

1

A

2

3

X   X

X   X

Summary of Contents for ComfoAir 160

Page 1: ...ComfoAir 160 Installer manual...

Page 2: ...has been compiled with the utmost care The publisher cannot be held liable for any damage caused as a result of missing or incorrect information in this manual In case of disputes the Dutch version o...

Page 3: ...7 2 6 2 Mounting on the wall 8 2 6 3 Connection of the air ducts 8 2 6 4 Connection of the condensation drain 9 2 7 Commissioning the ComfoAir 9 2 7 1 Display on the unit 10 2 7 2 CC Ease panel 10 2...

Page 4: ......

Page 5: ...4 months after fitting up to a maximum of 30 months after the date of manufacture Warranty claims may only be submitted for material faults and or construction faults arising during the warranty perio...

Page 6: ...this manual with the ComfoAir throughout its life Instructions with regard to cleaning or replacing the filters on the intake and exhaust valves must be carefully observed The specifications stated i...

Page 7: ...el L with connections for the CC Ease the enthalpy exchanger and the two 0 10 V controls Electronic box with PCB panel H with connections for the fans the bypass temperature sensors T1 to T4 the 3 pos...

Page 8: ...ng 112 m3 h at 57 Pa 0 25 A Maximum 157 m3 h at 110 Pa 0 52 A Electricity Power supply 230 50 V Hz Cos phi 0 52 0 56 Supply fan noise level at 0 m Position Ventilation capacity Sound power Absent Sett...

Page 9: ...0 52 0 56 Supply fan noise level at 0 m Position Ventilation capacity Sound power Absent Setting 29 m3 h at 4 Pa 42 dB A Low Setting 66 m3 h at 19 Pa 51 dB A Medium Setting 113 m3 h at 56 Pa 62 dB A...

Page 10: ...electrical connection Provisions for the condensation drain Wiring for an wired 3 position switch optional The cable used to connect the CC Ease panel must have the following specifications Cable type...

Page 11: ...12 Remove the 2 filters E from the ComfoAir 13 Place the back panel and the mounting brackets on the old front side 14 Place the removed filters in the new front side of the Com foAir 15 Place the fro...

Page 12: ...t level fix the mounting bracket hori zontally to the wall Make sure there is enough space under the ComfoAir to mount the siphon 2 Mount the ComfoAir on the wall 3 Mount the condensation drain under...

Page 13: ...nthalpy exchanger When the ComfoAir is fitted with an enthalpy exchanger the humidity from the extracted air is partly transferred to the fresh supply air In this case you delay the process of drying...

Page 14: ...10 x or press continuously 40 Select 40 7 OK P36 Value is 40 8 MENU P3 9 MENU 1 Fan setting Some P menus such as P1 and P9 can only be read Leaving Reading menu At action point 6 press MENU instead o...

Page 15: ...are preset in the software 7 Select a value for the parameter using or 8 Press to store the settings 9 Repeat steps 5 to 8 to set multiple parameters in succession Or Press to return to the P menu so...

Page 16: ...operating the bathroom switch the ComfoAir switches back to the normal setting Low voltage input 0 Min 120 Min 30 Min P23 Optional Note only applies to systems fitted with a hardwired 3 position switc...

Page 17: ...Note Only applies to systems fit ted with a CC Ease panel Timer for the Boost setting After pressing continuously 2 sec on the CC Ease panel the ComfoAir will switch to the high setting for x minutes...

Page 18: ...the supply fan to absent position 0 or 15 97 nL HL 15 15 P35 Setting the capacity in of the supply fan in low position 16 98 nL HL 35 40 P36 Setting the capacity in of the supply fan in medium positi...

Page 19: ...ING the signals from the analogue inputs 0 1 0 P59 Confirming the presence of an enthalpy exchanger 0 Enthalpy exchanger not fitted 1 Enthalpy exchanger with enthalpy sensor 2 Enthalpy exchanger witho...

Page 20: ...pears Menu P8 Setting the RF input and digital inputs 0 10V Analogue input values Submenu description Minimum Maximum General reset 810 Analogue input 1 0 not fitted 1 fitted 0 1 0 811 0 controlling 1...

Page 21: ...sed After 30 minutes the ComfoAir automatically terminates the programming mode 2 Close all windows and outside doors 3 Close all inside doors 4 Check the presence of structural overflow provi sions T...

Page 22: ...heck the heat exchanger once every 2 years 1 Disconnect the power from the ComfoAir 2 Remove the front panel by first removing the 6 protective caps A then the screws A 3 Re move the lower sensor D fr...

Page 23: ...f the malfunction alerts on the digital operating device In the chapter about trouble shooting it is explained how to solve these malfunctions Code description A1 NTC sensor T1 is defective outside ai...

Page 24: ...TC temperature sensors A1 A2 A3 A4 NTC sensor T1 T2 T3 T4 is defective Remove the cover of the electronic box by pressing in the 2 click connectors Reconnect the NTC sensor Reconnect the power to the...

Page 25: ...s Disconnect the power from the ComfoAir Replace the control circuit board Remove the motor Disconnect the power from the ComfoAir Is the cog of the motor defective Yes No Replace the cog of the motor...

Page 26: ...rs Is there 230 VAC power present on the fan Yes No Disconnect the power from the ComfoAir Replace the control circuit board Is a control signal 1 5 10 VDC present on the fan Yes No Disconnect the pow...

Page 27: ...thalpy sensor Yes Is P59 set to the correct value Yes No Set P59 to the correct value Reset the unit P74 on 1 Install all parts in reverse order Reconnect the power to the ComfoAir No Replace the conn...

Page 28: ...wer from the ComfoAir Replace the connection panel Are the connections at the ComfoAir correct Disconnect the power from the ComfoAir Are the connections at the CC Ease panel correct Reconnect the CC...

Page 29: ...filters with a vacuum cleaner Refit the handles to the ComfoAir Reconnect the power to the ComfoAir FILTER I Internal Filter is dirty Press on the CC Ease panel for at least 4 seconds until the filte...

Page 30: ...changer Fan dirty Clean the fan Ventilation ducts blocked Clean the ventilation ducts ComfoAir is in frost protection operation Wait until the weather warms up Too noisy Fan bearings defective replace...

Page 31: ...icle number 1 Connection PCB 400300068 2 Control PCB 400300067 3 Bypass Preheater motor 400200023 4 Temperature sensor T1 400300063 5 Temperature sensor T2 T4 400300063 6 Temperature sensor T3 4003000...

Page 32: ...EN 28 2 12 Wiring diagram ComfoAir 160...

Page 33: ...694 Company register Zwolle 05022293 EEC declaration of conformity Machine description Heat recovery units ComfoAir 160 series Complies with the following directives Machinery Directive 2006 42 EEC Lo...

Page 34: ...EN 30...

Page 35: ...31 EN...

Page 36: ...Zehnder Group Nederland B V Lingenstraat 2 8028 PM Zwole Nederland Tel 038 429 69 11 Fax 038 422 56 94 Internet www jestorkair nl E mail info jestorkair nl Zehnder Group Nederland B V 849050969 0212...

Reviews: