14
28.
Set MAX OPEN POSITION
Enter
Set PV
menu and move to
Open Position
with pressing + , or - and then press ENTER .
Set open position with pressing + , or - and then press ENTER .
Max open position is when curve is set to 100%. This open position can be moved to any position.
29.
PV Test
PV test can be used for testing, or measuring valve position. Valve can be moved to any position
from 0% to 100%, without engine running.
Enter
Set PV
menu and move to
PV Test
with pressing + , or - and then press ENTER .
Set valve position with pressing + , or - and then press ENTER .
30.
Set POWER-UP Test
Enabling, or disabling test cycle of PV servo at power-up.
Enter
Set PV
menu and move to
Power-up Test
with pressing + , or - and then press ENTER .
Enable, or disable power-up test with pressing + , or - and then press ENTER .
31.
PV CURVE SW
Enabling, or disabling PV curve switch for changing PV curves while riding.
Enter
Set PV
menu and move to
PV Curve SW
with pressing + , or - and then press ENTER .
Enable, or disable
PV Curve
switch with pressing + , or - and then press ENTER .
32.
MEASURING STATIC ANGLE
Measuring correct static angle is very important. Wrong static angle will cause inaccurate ignition
advance. If static angle is programmed larger than mechanical static angle then ignition advance will
be smaller than programmed, or vice versa.
The most accurate procedure of measuring static angle is with dial gauge and strobe light.