14 / 45
If the Remote Server A item in the Status page is still “Unpingable”, the configuration was not
successful, i.e. the wrong router password was entered or the device was disconnected during
connection.
It is necessary to reset the card:
-
Select Reset in the left-hand column.
-
Press OK to confirm.
-
Close the web page and enter the Status page again. At this point, the configuration
procedure can be repeated again.
Figure 17 – Reset screen
1.4.
Troubleshooting
1.
The AP_******** Wi-Fi network generated by the card installed on the inverter is not
visible
-
Check the Modbus address set on the inverter:
Enter the main menu with the ESC key (first key on the left), go to System Info and press
ENTER to enter the submenu. Scroll down to the Modbus address parameter and make
sure it is set to 01 (and in any case, other than 00).
If the value set is different from 01, go to Settings and enter the Modbus Address menu
where the 01 value can be set.