62 / 67
User’s Manual 3PH 100KTL-136KTL-HV
Rev. 1.0 24/02/2021
Identification: MD-AL-GI-00
Rev. 1.0 of 24/02/2021 - Application: GID
ID100
Reserved
ID102
HwPVOCP
PV hardware overcurrent
ID103
HwACOCP
AC output hardware
overcurrent
ID113
OverTempDerating
Overtemperature derating
This faulty only cause alarm, It will
not directly cause the system to enter a
fault state.
ID114
FreqDerating
Frequency derating
ID115
FreqLoading
Frequency loading
ID116
VoltDerating
Voltage derating
ID117
VoltLoading
Volatge loading
ID124
Reserved
ID125
Reserved
ID129
unrecoverHwAcOCP
Output overcurrent
hardwarepermanent fault
ID129-ID141are internal faults of
inverter, turn OFF the
“
DC switch
”
,
wait for 5 minutes, then turn ON the
“
DC
switch
”
. Check whether the fault is
rectified. If no, please contact technical
support.
ID130
unrecoverBusOVP
Busovervoltagepermanent
fault
ID131
unrecoverHwBusOVP
Busovervoltage hardware
permanent fault
ID133
Reserved
ID134
unrecoverAcOCPInstan
t
Output transient overcurrent
permanent fault
ID135
unrecoverIacUnbalanc
e
Output current imbalance
permanent fault
ID138
unrecoverPVOCPInstan
t
Input overcurrent permanent
fault
ID139
unrecoverHwPVOCP
Input hardware overcurrent
permanent fault
ID140
unrecoverRelayFail
Relay permanent fault
ID141
unrecoverVbusUnbalan
ce
Bus
Unbalanced permanent fault
ID145
USB Failure
ID145-ID158are internal faults of
inverter, turn OFF the
“
DC switch
”
,
wait for 5 minutes, then turn ON the
“
DC
switch
”
. Check whether the fault is
rectified. If no, please contact technical
ID146
WIFI failure
ID147
Bluetooth failure
ID148
RTCClock failure