Direct Access Keys ZaxNet Setup
29
TRX Off-On
This controls the standby status of the wireless transmitter(s) being controlled via ZaxNet.
•
ON
- When set to ON the transmitter(s) will transmit as normal.
•
WAKE UP
- When WAKE UP is selected any transmitter that has its power up mode set to “REMOTE
STANDBY” will wake up.
A transmitter that is set to Remote Standby, in the transmitter’s set up menu, will boot up to an ultra-low
power mode. Then when the wake command is sent from here the transmitter(s) wakes up to normal
transmit mode. This setting is useful for conserving battery power when a transmitter needs to be turned
on for an extended period of time before it will be needed. The only way to put the transmitter back into
remote standby is power cycle the transmitter. Please see the transmitter manual for more information
on enabling REMOTE STANDBY.
•
LOW (OFF)
- When a transmitter is put in LOW mode the RF power amplifier, RF board, and mic preamps
are disabled. This cuts the power consumption of the transmitter and extend its battery life. Transmitters
can be put into, and taken out of LOW mode at any time.
Send ERX Delay
The audio being transmitted to the ERX receiver(s) can be delayed. This would is useful to sync audio to
picture when there is a video processing delay. This setting only delays the audio being sent to the ERX
receivers and does not affect any other audio. Please note that this is a global setting, meaning that all ERX
receivers will receive the same delay. Delay can be set up to 400ms in 5ms increments.
ZaxNet TC Out
•
ON
- The time code being outputted from Nova will have embedded ZaxNet commands. ZaxNet TC out
should be on when feeding timecode to another Zaxcom device via the BNC output.
•
OFF
- The time code output will not have embed ZaxNet commands. ZaxNet TC out should be set to off
when feeding time code to a non Zaxcom device.
IFB Test Tone
When turned on a 1K test tone will be sent to the ERX receiver(s).
Update IFB Module
This is where the firmware for the ZaxNet transmitter module is updated from. The ZaxNet software is
already contained in the Nova software.
IFB Debug
This is a factory diagnostic menu
.