6.4 Description of Console “PROGRAM VACC” function
This function looks for and remembers the minimum and maximum potentiometer
wiper voltage over the full mechanical range of the pedal. It enables
compensation for non symmetry of the mechanical system between directions.
The operation is performed by operating the pedal after entering the PROGRAM
VACC function.
Flow Chart showing how to use the PROGRAM VACC function of the Digital
Console.
1) Opening Zapi Display.
AC2 ZAPI V0.0
48V 350A 00000
2) Press ENTER to go into the General Menu.
' % '
' ' '
3) The Display will show:
MAIN MENU
PARAMETER CHANGE
4) Press ROLL UP or ROLL DOWN button until
PROGRAM VACC appears on the display
% ' '
% ' '
5) The Display will show:
MAIN MENU
PROGRAM VACC
6) Press ENTER to go into the PROGRAM VACC
routine.
' % '
' ' '
7) The Display will show the minimum and
maximum values of potentiometer wiper output.
Both directions can be shown.
VACC SETTING
4.8 4.8
8) Press ENTER to clear these values.
Display will show 0.0.
' % '
' ' '
9) Select Forward Direction, close any interlock
switches that may be in the system.
MIN VACC MAX
0.0 - 0.0
10) Slowly depress the accelerator pedal (or tiller
butterfly) to its maximum value. The new minimum
and maximum voltages will be displayed on the
Console plus an arrow indicating the direction.
11) Select the Reverse Direction and repeat Item
10.
MIN VACC MAX
0.6
↑
4.4
12) When finished, press OUT.
' ' '
' % '
13) The Display will ask: “ARE YOU SURE”?.
ARE YOU SURE
YES=ENTER NO=OUT
14) Press ENTER for yes, or OUT for NO.
' % '
' % '
ADEZP0AE - AC-2 INVERTER - User Manual
Page - 53/64
Summary of Contents for AC-2
Page 21: ...4 8 Mechanical drawing ADEZP0AE AC 2 INVERTER User Manual Page 21 64...
Page 22: ...4 9 Connection drawing Traction configuration Page 22 64 ADEZP0AE AC 2 INVERTER User Manual...
Page 23: ...4 10Connection drawing Pump configuration ADEZP0AE AC 2 INVERTER User Manual Page 23 64...
Page 24: ...4 11Connection drawing Combi configuration Page 24 64 ADEZP0AE AC 2 INVERTER User Manual...