ANALOG: an analog motor thermal sensor is connected between F6
and F12 (the curve can be customized on a customer request).
-
NONE:
no motor thermal sensor switch is connected.
9) AUX
FUNCTION
-
ON/OFF:
if this option is programmed ON the traction inverter applies
maximum braking and traction torque.
10) ENABLE FUNCTION
-
PRESENT: input E14 is managed as accelerator enable input.
-
ABSENT: input E14 is managed as exclusive hydro input.
11) CHECK PUMP HYDRO
-
ON/OFF:
if this option is programmed ON, if the traction inverter
doesn’t receive any messages by the pump inverter from the CAN-BUS
line, the "CAN BUS KO" warning appears on the traction and the
maximum speed is reduced down to 10%. The traction also checks via
CAN that there aren’t alarms on pump. If pump is in alarm, the maximum
speed is reduced down to 10%, but in this case any alarm or warning
appears.
SUBMENU "ADJUSTMENTS"
1) SET POT BRK MIN
It records the minimum value of braking pedal potentiometer when the
braking pedal switch is closed; the procedure is similar to the "Program Vacc"
function (see chapter 6.4). This procedure must be carried out only if the
"Pedal braking" option is programmed as "Analog".
2) SET POT BRK MAX
It records the maximum value of braking pedal potentiometer when the
braking pedal is fully pressed; the procedure is similar to the "Program Vacc"
function (see chapter 6.4). This procedure must be carried out only if the
"Pedal braking" option is programmed as "Analog".
3) SET BATTERY TYPE
It selects the nominal battery voltage.
4) ADJUST
BATTERY
Fine adjustment of the battery voltage measured by the controller.
5) THROTTLE 0 ZONE
It establishes a deadband in the accelerator input curve (see also curve
below).
6) THROTTLE X POINT
This parameter changes the characteristic of the accelerator input curve.
7) THROTTLE Y POINT
This parameter changes the characteristic of the accelerator input curve.
VACC MIN and VACC MAX are values programmable by the "Program
ADEZP0AE - AC-2 INVERTER - User Manual
Page - 29/64
Summary of Contents for AC-2
Page 21: ...4 8 Mechanical drawing ADEZP0AE AC 2 INVERTER User Manual Page 21 64...
Page 22: ...4 9 Connection drawing Traction configuration Page 22 64 ADEZP0AE AC 2 INVERTER User Manual...
Page 23: ...4 10Connection drawing Pump configuration ADEZP0AE AC 2 INVERTER User Manual Page 23 64...
Page 24: ...4 11Connection drawing Combi configuration Page 24 64 ADEZP0AE AC 2 INVERTER User Manual...