Before carrying out any maintenance or clea-
ning isolate the cooker hood from the mains 
supply.

 

The cooker hood must be kept clean, as a build 
up of grease or fat can be a 

fi

 re hazard.

External Cleaning

Wipe the cooker hood frequently with warm
soapy water using a mild detergent.

 

Never use scouring pads or abrasive cleaners.

 

Never use excessive amounts of water when 
cleaning particularly around the control panel.

Metal Grease Filters

The 

fi

 lters are washable and must be cleaned when the 

Led S1

 lights up or at least every 2 months of opera-

tion, or more frequently for particularly heavy usage.

 

Remove the metal grease 

fi

 lters 

one at a time by:

 

Releasing the catches on the 

fi

 lters, the

 

fi

 lters can be removed.

The metal grease 

fi

 lters should be washed, by

hand, in mild soapy water or in a dishwasher. Allow
to dry completely before replacing.

 

Alarm signal reset

 

Switch off the lights and extractor motor.

 Press 

Button 

T3 

for at least 3 seconds, until  

the leds start to 

fl

 ash.

MAINTENANCE AND CLEANING

Summary of Contents for ZHC945

Page 1: ...COOKER HOOD ZHC945 INSTRUCTION BOOKLET ...

Page 2: ......

Page 3: ...lease ensure you complete and return the guarantee card supplied with the appliance For the User Important Safety Information Your Appliance Operating Instructions Cooker Hood Controls To Operate Recirculation Extraction Maintenance and Cleaning External Cleaning Metal Grease Filters Charcoal Filters To Remove Replace Charcoal Filter Changing the Halogen Light Something Not Working Service and Spa...

Page 4: ...tor has cooled significantly It is dangerous to alter the specifications or modify this product in any way When installed between adjoining wall cabinets the wall cabinets must not overhang the hob If the room where the hood is to be used contains a fuel burning appliance such as a central heating boiler then its flue must be of the room sealed or balanced flue type If other types of flue or appli...

Page 5: ...5 YOUR APPLIANCE ...

Page 6: ... Suitable for the strongest cooking vapours and odours The function becomes active when the button is pushed for about 2 seconds After 10 minutes of functioning it turns off automatically This function can be interrupted by means of pressing any of the buttons S1 Led Fixed Indicates that the Metal grease filters saturation alarm has been triggered and the filters need to be washed The alarm is tri...

Page 7: ...e grease filters and is passed out through the ducting into the atmosphere To obtain the best performance when cooking it is advisable to switch the cooker hood on for a few minutes before you start cooking and leave it running for about 15 minutes after finishing When used in the ducting mode the charcoal filters are not required Never do flambé cooking under this cooker hood Never leave frying p...

Page 8: ...the control panel Metal Grease Filters The filters are washable and must be cleaned when the Led S1 lights up or at least every 2 months of opera tion or more frequently for particularly heavy usage Remove the metal grease filters one at a time by Releasing the catches on the filters the filters can be removed The metal grease filters should be washed by hand in mild soapy water or in a dishwasher...

Page 9: ...es or at least every 4 months The alarm signal will only light up when the extractor motor is switched on To Remove Replace the Charcoal Filters Remove the metal grease filters Remove the saturated activated carbon filter by releasing the fixing hooks Fit the new filter by hooking it into its seating Replace the metal grease filters This appliance can be a possible fire hazard if the grease and ch...

Page 10: ...that the charcoal filter is still effective If set up for extraction check that the ducting and outlets are not blocked The safety cut out device has been tripped Tum off the hob and then wait for the device to reset In guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown If you require an...

Page 11: ...Costs incurred for calls to put right appliances improperly installed or calls to appliances outside the United Kingdom Appliances found to be in use within a commercial environment plus those which are the subject of rental agree ments Products of Zanussi manufacture which are not marked by Zanussi This guarantee is in addition to your statutory and legal rights ZANUSSI EUROPEAN GUARANTEE If you ...

Page 12: ...voltage corresponds to the voltage on the rating plate inside the cooker hood This appliance is fitted with a 3 core mains cable and must be permanently connected to the electricity supply via a double pole switch having 3mm minimum contact gap on each pole A Switched Fuse Connection Unit to BS1363 Part 4 fitted with a 3 Amp fuse is a recommended mains supply connection accessory to ensure complia...

Page 13: ...d competent person The manufacturer disclaims any responsibility for damage due to incorrect installation of the cooker hood or if the hood is not installed in compliance with relevant regulations controlling this type of installation Unpacking Before unpacking the cooker hood position the carton with the arrows pointing upwards as illustrated on the carton The cooker hood is made up of the follow...

Page 14: ...red when installed above a slot in electric cooker or 787mm 30 1 2 when installed above a slot in gas cooker When installed between adjoining wall cabinets the wall cabinets must not overhang the hob and the distance between the underside of the cabinet and the worktop must be 450mm If the height of the wall cabinet is less than 450mm a gap of 50mm must be maintained either side of the hob This co...

Page 15: ...ark the wall at the centres of the holes in the bracket Mark a reference point as indicated at 116 mm from the vertical reference line and 306 mm above the horizontal reference line Repeat this operation on the other side Drill ø 8 mm holes at all the centre points marked Insert the wall plugs not supplied in the holes Fix the lower bracket 7 2 1 using the two screws not supplied Fix the upper bra...

Page 16: ...rformance use the shortest possible run of ducting and we recommend the use of rigid pipe in preference to flexible hose as this will improve the flow of air while reducing turbulence which causes causes noise and a loss of performance If the room where the cooker hood is to be used contains a fuel burning appliance such as a central heating boiler then its flue must be be of the room sealed or ba...

Page 17: ...sides to the brackets using the 4 screws 12c 2 9 x 9 5 supplied Make sure that the outlet of the extensions pieces is aligned with the chimney outlets Lower exhaust flue Slightly widen the two sides of the flue and hook them between the upper flue and the wall making sure that they are well seated Fix the lower part laterally to the hood body using the 2 screws 12c 2 9 x 9 5 supplied ...

Page 18: ......

Page 19: ......

Page 20: ... Electrolux plc 2002 436002548_03 070319 ...

Reviews: