Mounting the hood body
• Before attaching the hood body, tighten the two screws
Vr
located on the hood body mounting points.
• Hook the hood body onto the screws 12a
• Fully tighten support screws 12a
• Adjust screws
Vr
to level the hood body.
INSTALLING THE COOKER HOOD
Extraction (Ducted)
The cooker hood is more effective when installed in the
extraction mode (ducted to the outside).
Venting kits may be purchased through your retailer or DIY
store, and must be evacuated through an outside vent of
ø125 (5ins) or ø150mm (6ins).
The ducting used must be manufactured from fire
retardent material conforming to the relevant British
Standard or DIN 4102-B1.
When the cooker hood is ducted to the outside the
charcoal
fi
lter must be removed.
Fitting the Ducting
• Fit the ø150mm (6ins) ducting to the spigot on top of
the hood body as illustrated.
• When using ø125mm (5ins) ducting
fi
t
item 9
and
10
on to the spigot on the top of the hood body as
illustrated.
• For the best performance use the shortest possible run of ducting and we recommend the use of rigid pipe in
preference to
fl
exible hose as this will improve the
fl
ow of air while reducing turbulence, which causes causes
noise and a loss of performance.
• If the room where the cooker hood is to be used contains a fuel burning appliance such as a central heating boiler,
then its
fl
ue must be be of the room sealed or balanced
fl
ue type.
• If other types of
fl
ue or appliances are
fi
tted ensure that there is an adequate supply of air to the room.
• The cooker ducting when
fi
tted in the evacuation mode must never be connected to central heating
fl
ues,
radiators or water heaters.
Recirculation version Air Outlet
• Put connection
15
into the connection support
7.3.
• Insert the connection extension pieces laterally
14.1
in connection
15
.
• Make sure that the outlet of the extension pieces
14.1
is horizontally and vertically aligned with the
chimney outlets.
• Connect the air outlet connection
15
to the hood body
outlet using either a
fl
exible or rigid pipe ø 150 or
120 mm, the choice of which is left to the installer.
• Ensure that the activated charcoal
fi
lters have been
inserted.