19
GB
USE
Control panel
L
Light
Switches the lighting system on and off.
S1
Led
Motor running led.
S2
Led
Optimum speed led.
S3
Led
Intensive speed led.
S4
Led
Grease filters saturated alarm led.
S5
Led
Activated charcoal filter exhausted alarm led.
To disable this indicator (Ducted hoods) simultaneously press buttons R (using
a sharp object, for example a pencil) and V2. To enable it again, press buttons R
and V3.
R
Reset
Internal Filter Alarms Reset button.
V1
Motor
Switches the extractor motor on and off.
V2
Speed
Decreases the operating speed.
V3
Speed
Increases the operating speed.
V4
Optimum
Preset optimum speed. To customise the Optimum speed setting, select the Speed
speed
you require using buttons V2 and V3 then press V4 within 10 seconds (during
this period the corresponding led S2 will flash). The setting you enter will remain
active until the Hood is turned off.
V5
Intensive
Maximum speed, used to eliminate the highest levels of cooking vapour
speed
emission. Returns to Optimum speed automatically after it has been in operation
for 15 minutes. Intensive speed can also be turned off manually by pressing
button V4.
T
Delayed
This device allows any residual odours to be removed without having to wait
shutdown
and turn the appliance off, as the Motor and Lighting will switch off automatically
at the end of the selected time.
By pressing button T in succession it is possible to set the delayed shutdown of
the appliance to 15, 30 and 60 minutes, respectively. The selected time is shown
by leds T1, T2, T3. To move from one time to another, simply press button T
until the required led lights up. The time selected in this way will start from
zero. The delayed shutdown function can be turned off by pressing button V4.
T1
Led
15’ delayed shutdown indicator led.
T2
Led
30’ delayed shutdown indicator led.
T3
Led
60’ delayed shutdown indicator led.
0 - 1
0 - 1
15
30
60
reset
reset
delay
L
S1
V1
V2
V3
V4
V5
T
S2
S3
S4
T1 T2 T3
S5
R