background image

17

GB

Upper frame
• Align the power supply cable feed hole
• Fix the upper frame to the ceiling or shelf using:

•  For concrete ceilings, use the appropriate plugs for the screw size (not provided).
•  For hollow brick ceilings of wall thickness of approximately 20 mm: use 4 plugs 11 and 4

screws 12h, provided.

•  For wooden beam ceilings, use 4 wood screws (not provided).
•  For wooden shelf, use 4 screws 12g with washers 22 and nuts 23, provided.

Lower frame
• Fix the lower frame using the 8 previously removed screws, adjusting the length according to the

installation height (hood body lower fixing surface must be at least 720 mm from the hob).

• For the recirculation version, turn the frame in the direction chosen for the recirculated air outlet.

• The frame mountings must be secure to withstand the weight of the hood and any stresses caused

by the occasional side thrust applied to the device. On completion, check that the base is stable,
even if the frame is subjected to bending.

• In all cases where the ceiling is not strong enough at the suspension point, the installer must

provide strengthening using suitable plates and backing pieces anchored to the structurally sound
parts.

Connections

DUCTED VERSION AIR EXHAUST SYSTEM

When installing the ducted version, connect the hood to the chimney using either a flexible or rigid
pipe ø 150 or 120 mm, the choice of which is left to the installer.

• To install a ø 120 mm air exhaust connection,

insert the reducer flange 9 on the hood body
outlet.

• Fix the pipe using the pipe clamps 25 provided.
• Remove any activated charcoal filters.

RECIRCULATION VERSION AIR OUTLET

• Insert reducer flange 9 on the extractor outlet.
• Push fit the extension piece 14 onto the flange.
• Push fit connector 15  onto the extension piece.
• Insert extension piece/connector 14.1 laterally

on connector 15, ensuring that the outlet is in
line with the chimney intake.

9

ø 120

ø 150

15

14.1

14

9

Summary of Contents for ZHC 928

Page 1: ...kap ZHC 928 MANUALE DI INSTALLAZIONE USO E MANUTENZIONE INSTALLATION USE AND MAINTENANCE HANDBOOK MANUEL D INSTRUCTIONS POUR L INSTALLATION L EMPLOI ET L ENTRETIEN HANDBUCH FÜR INSTALLATION BEDIENUNG UND WARTUNG INSTRUCTIES VOOR MONTAGE GEBRUIK EN ONDERHOUD ...

Page 2: ...recommendations contained in this Instruction Manual your appliance will give you constant high performan ce and will remain efficient for many years to come RECOMMENDATIONSAND SUGGESTIONS 13 CHARACTERISTICS 14 INSTALLATION 16 USE 19 MAINTENANCE 20 ...

Page 3: ...f aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air USE The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells Never use the hood for purposes other than for which it has ben designed Never leave high nak...

Page 4: ...14 GB CHARACTERISTICS Dimensions 790 min 970 max 68 512 790 898 730 ø 340 ...

Page 5: ... 1 Reducer Flange ø 150 120 mm 14 1 Hood Body Air Outlet Extension Piece consisting of two Half Shells 14 1 1 Air Outlet Connection Extension 15 1 Air Outlet Connection 25 2 Pipe clamps Ref Q ty Installation Components 11 4 Wall Plugs ø 10 12b 3 Screws 2 9 x 4 5 12f 4 Screws 3 5 x 9 5 12g 4 Screws M6 x 80 12h 4 Screws 5 2 x 70 21 1 Drilling template 22 4 6 4 mm int dia washers 23 4 M6 nuts Q ty Do...

Page 6: ... For concrete ceilings drill for plugs appropriate to the screw size For hollow brick ceilings with wall thickness of 20 mm drill ø 10 mm For wooden beam ceilings drill according to the wood screws used For wooden shelf drill ø 7 mm For the power supply cable feed drill ø 10 mm For the air outlet Ducted Version drill according to the diameter of the external air exhaust duct connection FIXING THE ...

Page 7: ...de thrust applied to the device On completion check that the base is stable even if the frame is subjected to bending In all cases where the ceiling is not strong enough at the suspension point the installer must provide strengthening using suitable plates and backing pieces anchored to the structurally sound parts Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version co...

Page 8: ...d from below use the 4 screws 12f provided to fix the hood body to the frame For the recirculation version locate the directional grill 8 in its housing Ensure that it is inserted correctly in connector 15 ELECTRICAL CONNECTION Connect the hood to the mains through a two pole switch having a contact gap of at least 3 mm Take off the upper protection bracket by unscrewing the screws Connect the con...

Page 9: ...ned off V5 Intensive Maximum speed used to eliminate the highest levels of cooking vapour speed emission Returns to Optimum speed automatically after it has been in operation for 15 minutes Intensive speed can also be turned off manually by pressing button V4 T Delayed This device allows any residual odours to be removed without having to wait shutdown and turn the appliance off as the Motor and L...

Page 10: ...ters The filters are washable and must be cleaned when led S4 flashes or at least every 2 months of operation or more frequently for particularly heavy usage Remove the filters one at a time by pushing them towards the back of the group and pulling down at the same time Wash the filters taking care not to bend them Allow them to dry before refitting When refitting the filters make sure that the ha...

Page 11: ... Alarm indicator led S5 will go out Replacing the Filter Remove the metal grease filters Remove the saturated activated carbon filter by releasing the fixing hooks Fit the new filter by hooking it into its seating Replace the metal grease filters Lighting LIGHT REPLACEMENT 20 W halogen light Remove the 2 screws fixing the ring nut Extract the lamp from the lamp holder by pulling gently Replace wit...

Page 12: ...conforme à la norme européenne sur la basse tension C E E 73 23 relati ve à la sécurité électrique et aux normes européennes C E E 89 336 relative à la compatibilité électromagnétique et C E E 93 68 relative au marquage CE Dieses Gerät entspricht den europäischen Niederspannungsrichtlinien 73 23 EWG zur elektrischen Sicherheit den europäischen Richtlinien 89 336 EWG zur elektromagnetischen Verträg...