20
OVEN LAMP REPLACEMENT
Ensure that the appliance is switched off
before replacing the lamp to avoid possibility
of electric shock.
This lamp of 15 W, convection E 14 (230/240V)
is
a special
lamp for “higher” temperature
, up to
300°C. It is
supplied on order, by your After Sales
Service.
The lamp is fixed in front of the oven and is
accessible from inside.
For reaching the lamp:
1. Unscrew the glass lamp protection (fig. 23);
2. Unscrew the lamp;
3. Replace the lamp;
4.
Remount the lamp protection
During use the appliance becomes hot.
Care should be taken to avoid touching
heating elements inside the oven.
fig. 23
CHANGE OF GAS
Your cooker is foreseen to work with natural gas,
propane or butane. It is not foreseen for butane or
propane air.
For changing the gas type it is necessary to:
•
replace the nozzles (hob);
•
adjust the minimum level;
•
check the gas connection.
SPECIFICATION NOZZLES NO. 2
(Cat
: II
2E+ 3+
)
(
Cat : II
2H 3B/P
)
Cons.
Burner
Normal
power
(Kw)
Reduced
power
(Kw)
By-pass
(mm)
Gas type
Pressure
(mbar)
Nozzle
diameter
(mm)
g/h
m
3
/h
RAPID
2,60
0,72
0,42
Natural gas G20
Butane G30
Propane G31
20
28-30
37
1,12
0,86
0,86
188,8
0,248
SEMIRAPID
2,00
0,43
0,32
Natural gas G20
Butane G30
Propane G31
20
28-30
37
0,96
0,71
0,71
145,2
0,191
AUXILIARY
1,00
0,35
0,29
Natural gas G20
Butane G30
Propane G31
20
28-30
37
0,70
0,50
0,50
72,6
0,093
Stick the label delivered with the
appliance (spare nozzles, corresponding to
the type of gas used).