17
INSTALLATION
Placement
Remove the plastic packaging and install the
cooker in a dry, ventilated room (fig. 18) not near
curtains, paper, alcohol, petrol, etc…)
The appliance has to be set on a heatproof soil.
This appliance belongs to class “X” in matters of
protection against overheating of surrounding
surfaces.
It is mandatory to keep 2cm distance to the
furniture walls.
Ventilation
Gas combustion is possible due to the oxygen in
the air (2 m
3
air/h x kW installed power – check
the rating panel of the cooker).
It is necessary to renew the air and that the
combustion products be discharged.
The air flow must come directly through openings
of external walls having a free passage of at least
200 cm
2
.
These openings should be realized preferably
positioned near the floor, opposite the combustion
products discharge. It should not be occluded both
from inside and outside.
Gas connection
Your cooker is delivered adjusted for the kind of
gas stated on the rating plate.
It might be necessary to pass to another kind of
gas, different to the one it is preset to. Under
these circumstances follow the instructions
bellow.
For best efficiency, lowest consumption and
a longer length of life of your cooker, the manifold
gas pressure has to respect the values shown in
table no. 2.
If the appliance is supplied with Butane or Propane
gas check that from the pressure regulator, the
pressure for Butane is 28 mbar and for Propane is
37 mbar.
Connection using a rigid pipe or a flexible
pipe (class 1).
1. For network gas:
Flexible, nonmetal pipe
•
Use a flexible rubber pipe non longer than 1,5
m and inner diameter of 15 mm mounted with
its holder
•
Make sure it is well inserted and
fix it by
means of a collar.
2 cm
2 cm
61 cm
1
5
4
3
2
C G L 4 0 4
min
min 15 cm
fig. 18
Fitting
Necklace
Connection
gas
Pipe
flexible
fig.19
Summary of Contents for ZCM5160
Page 1: ...0 INSTRUCTION BOOK ELECTRIC GAS COOKER ZCM 5160 ...
Page 9: ...8 fig 5 ...