19
Note:
In case of a direct connection to the mains you
have to interpose an omnipolar switch a minimum
opening between contacts of 3 mm.
The switch should be sited within 2m of the hob
and be easily accessible upon completion of the
installation.
The yellow-green grounding cable has not to be
interrupted by the switch.
Ensure that the supply cord is not in
contact with
any part of the hatched
area shown in the diagram
(fig.22).
NOTE
:
The earth wire should be about 2 cm
longer than the live and neutral wires.
Use the cable with the section indicated in the
table no.1.
Before connecting check that:
•
fuse and household electric installation can
bear the charge of the appliance (see rating
plate);
How to proceed?
•
Unscrew and remove the protective cover at
the back of the appliance;
•
Connect the power cord to the terminal of the
cooker according to the table no.1;
•
Fix by means of cable clamp;
•
Make sure that the connection to the terminal
is matching the network power;
•
Remount and screw the protective cover at the
back of the appliance.
Table no.1
Connection type
Single phase
Tri-phase
Tri-phase Y 3 ph. +
neutral
Tri-phase Y 2 ph. +
neutral
Cable connection to the
terminal plate
1 2 3 4 5
L1
N
PE
L3
5
1 2 3 4
L1
L2
PE
3
1
L3
L1
PE
4 5
N
L2
2
4 5
N
PE
2 3
L2
L1
1
Network power
230 V
230 V
230 V / 400 V
230 V / 400 V
Voltage of heating
elements
230 V
230 V
230 V
230 V
Fusible capacity
20 A
20 A
16 A
16 A
Cable section
3 x 4 mm²
4 x 4 mm²
5 x 2,5 mm²
4 x 2,5 mm²