3.5 Other technical data
WARNING!
These instructions are only valid in the
countries whose symbols appear on this
booklet's cover.
Gas category:
I2H
Gas supply:
G20 (2H) 20 mbar
Voltage:
220-240 V
Frequency:
50 Hz
3.6 Gas burners
BURNER
NORMAL POWER
kW
Natural Gas
INJECTOR MARK 1/100 mm
Btu/h
Auxiliary
0.95
70
3242
Semi-rapid
1.9
96
6483
Multi crown
3.4
136
11600
Semi-rapid
1.9
96
6483
Top Oven
1.7
95
5804
Main Oven
1.7
95
5804
3.7 Gas Connection
Use a flexible pipe in compliance with the
regulation in force. Make sure they do not
come in touch with mobile parts and are not
squeezed.
WARNING!
Only a qualified and competent person
can do the gas installation.
Before you connect te gas, disconnect
the appliance from the electricity supply
or switch off the fuse in the fuse box.
Close the primary valve of the gas
supply.
Supply piping should not be less than
R3/8. Connection is made to the Rc 1/2
(1/2 “ B.S.P.) female threaded. The entry
pipe is located just below the hob level
on the rear left hand side of the
appliance.
The gas supply ramp is on the rear side
of the appliance.
WARNING!
Only liquid sealants can be used when
the inlet gas pipe is fitted i.e.: do not use
the P.T.F.E. sealant tape.
When the installation is complete, carry
out a gas tightness test and make sure
that the seal of each pipe fitting does not
leak.
Use flexible tubing, which comply with
the BS.669 current edition.
ENGLISH 9