LIBERO LINE WOK INDUCTION
HOW
TO
RECOGNIZE
PHASE
AND
NEUTRAL
The appliance is equipped with a power cord and socket, however, in case of need , some basic tips on how
to check the supply wires before our main terminal board.
Double zone appliances are three phase supplied : L1+L2+L3 +N
Single zone is single phase supplied: L+N
Put your meter in AC Volts setting. Connect supply to the main terminal board
MA
but do not turn on the ap-
pliance. Connect the meter test leads to the terminal board contacts; the readings should be:
L1 / L2 / L3 + N* (Phase and Neutral) =
230 Volts
(+/- 6% based on European standards)
L1 / L2 / L3 + (Phase and Earth) =
230 Volts
L1 and/or L2 + L3 (Phase and Phase) =
400 Volts
N + (Neutral and Earth) =
0 Volts
(or approx. zero V)
The combination and results obtained will permit you
to find all wires: PHASE, NEUTRAL and EARTH.
RESIDUAL
CURRENT
The contact opening max. distance and leakage current must comply with the local safety regulations.
Many countries use a 30mA, but you must refer to the local regulations!!
WARNING!
Take GREAT CARE when testing anything with live current and always use your personal protective
equipment; if you are unsure what you are doing and how to use your equipment safely then
DON'T
DO IT
Summary of Contents for LIBERO IWOKEC-1P/1ZT
Page 1: ...Service Manual Wok Induction IWOKEC 1P 1ZT Art 406600893 2021 04 ...
Page 15: ...15 LIBERO LINE WOK INDUCTION 3P WOK SA 3PH SZ DI ...
Page 50: ...50 LIBERO LINE WOK INDUCTION ...
Page 51: ...51 LIBERO LINE WOK INDUCTION ...
Page 53: ...53 LIBERO LINE WOK INDUCTION ...
Page 54: ...54 LIBERO LINE WOK INDUCTION ...
Page 56: ...56 LIBERO LINE WOK INDUCTION ...
Page 57: ...57 LIBERO LINE WOK INDUCTION ...
Page 60: ...60 LIBERO LINE WOK INDUCTION ...
Page 62: ...62 LIBERO LINE WOK INDUCTION NOTE E1 21 IS AN INVENTED ALARM JUST FOR ILLUSTRATION PURPOSE ...
Page 68: ...68 LIBERO LINE WOK INDUCTION APPLIANCE CASING ...