Weekly maintenance tasks
48
HDK350_EN_01_2005-05-10
Weekly maintenance tasks
Check differential pressure on the filters
►
Check the differential pressure on the pressure gauge of the filter.
The differential pressure should be 0.6-0.8 bar max. If the differential pressure
exceeds 0.6-0.8 bar, we recommend that you replace the filter element (see
page 48). The filter elements must be replaced in any case every year.
Check pressure settings at the pressure reducer
►
At the manometer (1), check pressure
settings of the pressure reducer.
The pressure should be set to 8 bar.
►
If the pressure is set to a value above or
below 8 bar, turn the thumbscrew (2) to
adjust the pressure reducer settings.
Pressure reducer with manometer
Maintenance work to be completed every 12 months
Renew filter elements on the filters
The filter elements must be replaced every 12 months.
►
Depressurise dryer and take out of service (see page 43).
►
Remove the bottom section of the filter
housing (see figure).
►
Replace filter element.
►
Refit bottom section of the filter
housing: first screw on very tightly,
and then unscrew by a quarter turn.
►
Dispose of used filter element in
accordance with the applicable
regulations.
►
Restart dryer (see page 44). Check
the all filters for leaks.
Open filter