Regular maintenance intervals
46
HDK350_EN_01_2005-05-10
Regular maintenance intervals
Note:
If a vessel has been depressurised, e.g. after completion of the
expansion phase, and the pressure remains above 0 bar, the vessel is
pressurised by what is known as ram pressure. This might be due to
blockage at the muffler(s),
contamination of the dust sieves,
spent drying agent.
To prevent such malfunctions, regularly service the dryer as described
below.
The table provides an overview of the maintenance work to be carried out. The
individual tasks are described in the following pages.
Maintenance interval
Component
Maintenance task to be carried out
daily
weekly
12 months
24 months
48 months
see page
Complete dryer
Carry out visual and function checks.
▲
47
Vessel pressure gauge
Check dam pressure. For a dam pressure
exceeding 0.3 bar:
– Check muffler.
– Check dust sieve.
– Check drying agent.
▲
48
Upstream and
downstream filters
Check differential pressure on the upstream
and downstream filters.
▲
48
Pressure reducer
Check pressure settings; adjust , if necessary.
▲
52
Upstream and
downstream filters
Replace all filter elements.
z
48
Muffler
Renew.
z
49
Dew point sensor (with
optional dew point
sensing-control
Must be calibrated.
z
50
Check valves
Clean, replace, if necessary.
z
51
Dust sieves, drying agent Renew.
z
52
Codes:
▲
Check.
z
Renew.
When carrying out any maintenance work, comply with the following safety
instructions: