27
(OPTIONAL)
26
(OPTIONAL)
47
17
44
52
50
58
(AS APPLICABLE)
(AS APPLICABLE)
(AS APPLICABLE)
CB12
CB11
CC
M2/14
M1/11
CB11
T1
G
71
B
HEATER1
HEATER2
HEATER1
T3
F
T1
F
T2
F
T3
G
T1
G
T2
G
T2
F
T1
F
T3
F
73
A
71
A
72
A
HC1
HC1
72
A
71
A
73
A
1 OR 2
28A
2
240
1
6 KW
6 KW
12 KW
Note: Heater 2 connection is applicable only for units with 10 to 20 kw heating.
20 KW
15 KW
HEATER2
10 KW
7.5 KW
1 OR 2
1 OR 2
10 KW
7.5 KW
(VOLT-FREE CONTACTS)
SM-4
41A
FR
COMP. ON/OFF/TRIP & UNIT TRIP
UNIT STATUS INDICATION CONNECTION
(REMOVE JP7)
----
10 K.W
5 K.W
6 K.W
10 K.W
7.5 K.W
T3
G
T2
G
----
1
7.5 KW
10 KW
5 KW
1
1 OR 2
----
5 KW
5 KW
6 KW
1
1
----
HTG.
HC2
73
B
72
B
TYPE-I
HEATER DATA TABLE
HTR1
STG.
HTR2
TYPE-II
TYPE-III
COMP
OIL PRESSURE SWITCH CONN.
OPS-1
27
CR2-1A
2
(OPTIONAL)
17
28
2
TO HVTB
(NOTE 5)
25
TO ATB
TO ATB
1A
1
(REMOVE JP1)
2
8
UVM-1
1
L1
L2
L2
L1
L2
UVM
L3
L3
UVM CONNECTION
(REMOVE JP5)
26
DTS
DTS CONNECTION
AI1
25
ANTI-ICE CONNECTION
46
AR1-1A
AR1-1B
45
UNIT ON
UNIT OFF
C. UNIT ON/OFF
15
AR1
BM TRIP
FR-1
43
BM OFF
BM ON
51
OLR-2
BMC-1A
48
49
BMC-1B
UNIT TRIP
57
56
55
COMP1 0FF
COMP1 TRIP
COMP1 ON
CCA
-2A
54
FR-2B
OPS
T2
A
T1
A
T3
A
(REMOVE JP4)
1
L1/MP/L
L2/R/N
DUAL STAGE HEATING
HEATER CONNECTION DETAILS
L1
L3
L2
L2 L3
L1
SINGLE STAGE HEATING
TO HVTB
TO HVTB
CONNECTION
SCROLL COMP.
L2 L3
L1
FL
FL
FL
OHT
HEATER BOX CONNECTION TYPES
T2
T1
T3
TO HVTB
OHT
T2 T3
T1
T1
T2
T3
OHT
L1
A
L2
A
L3
A
CB1
COMP. SSPS CONNECTION
24
SSPS
L2
L1
L3
(OPTIONAL)
TO HVTB
100A
RECIP. COMP.(Semi-Hermetic)
1
CR2-1B
C.HTR
L1
C.HTR
(OPTIONAL)
COMPRESSOR CKT. BREAKER
CRANKCASE HEATER CONNECTION
3A
CR2
2
FR-2A
(REMOVE JP6)
2
230Vac
SERVICE LAMP CONNECTION
1
SW
98
LAMP
(OPTIONAL)
CCA
-2B
B. BM ON,OFF & TRIP INDICATION
LEGEND
AI
ANTI ICE THERMOSTAT
AFS
AIR FLOW SWITCH
AR
AUXILIARY RELAY
ATB
AUXILIARY TERMINAL BLOCK
BM
BLOWER MOTOR
BMC
BLOWER MOTOR CONTACTOR
CC
COMPRESSOR CONTACTOR
CB
CIRCUIT BREAKER
C. HTR CRANKCASE HEATER
CR
CONTROL RELAY
COMP
COMPRESSOR
DTS
DISCHARGE TEMPERATURE SENSOR
FL
FUSE LINK
FCS
FAN CYCLING SWITCH
FM
FAN MOTOR (CONDENSER)
FMC
FAN MOTOR CONTACTOR
FR
FAULT RELAY
HC
HEATER CONTACTOR
HPS
HIGH PRESSURE SWITCH
HVTB
HIGH VOLTAGE TERMINAL BLOCK
H
HEATER
JP
JUMPER
L1
LINE 1
L2
LINE 2
L3
LINE 3
LPS
LOW PRESSURE SWITCH
LUG
LUG GROUND
LLS
LEAD LAG JUMPER IN SM
NTB
NEUTRAL TERMINAL BLOCK
OLR
OVER LOAD RELAY
OHT
OVER HEAT THERMOSTAT
PDSR
PUMP DOWN SOLENOID RELAY
SM
SYSTEMIZER
SR
SAFETY RELAY
SSPS
SOLID STATE PROTECTIVE SYSTEM
TK
MOTOR THERMAL CONTACT
TRANS TRANSFORMER
T'STAT THERMOSTAT
UVM
UNDER VOLTAGE MONITOR
YR
COOLING RELAY
FIELD WIRING
DISCONNECT TAB - 1/4"
SPLICE-CLOSED END
TYPICAL SCHEMATIC WIRING DIAGRAM
(Single compressor units)
NOTES
1. POWER SUPPLY, REFER TO UNIT NAMEPLATE.
2. ANY WIRE REPLACEMENT SHOULD BE OF THE 90
0
C
OR ITS EQUIVALENT.
USE COPPER CONDUCTOR WIRES ONLY.
3. POWER MUST BE SUPPLIED TO CRANKCASE
HEATER FOR MINIMUM OF 12 HOURS PRIOR TO
SYSTEM START UP.
IF POWER IS OFF 6 HOURS OR MORE, CRANKCASE
HEATER MUST BE ON FOR 12 HOURS BEFORE
OPERATING THE SYSTEM.
FAILURE TO FOLLOW THESE INSTRUCTIONS MAY
RESULT IN COMPRESSOR DAMAGE.
4. FUSED DISCONNECT SWITCH OR CIRCUIT
BREAKER TO BE PROVIDED BY END USER WITH
RATING AS RECOMMENDED BY ZAMIL.
5. COMPRESSOR IS PROVIDED WITH INHERENT
THERMAL OVERLOAD PROTECTION.
6. FOR ANY SAFETY TRIP OF COMP. (FAULT), VOLTAGE
ACROSS TERMINAL 4 & 2 OF SYSTEMIZER IS 24 VAC.
ALSO COMPRESSOR LOCKOUT LIGHT IS ON.
7. NEUTRAL LINE REQUIRED ON 380V-3Ph-60Hz
POWER SUPPLY ONLY.
_ _ _
+
15