2
1, 2 & 3
BASIC
4, 5 & 6
NOMINAL
COOLING
CAP
ACITY
(MBH)
8
REFRIGERA-
TION CIR-
CUIT
7
ELECTRICAL
SUPPL
Y
( V
-Ph-Hz )
10
CONDENSER COIL
13
UNIT
CONFIGURA
TION
PDS
CLASSIC
DOUBLE SKIN
PACKAGED
UNIT
036
048
060
075
090
100
120
150
180
220
240
300
360
420
480
540
600
660
720
780
840
S
:SINGLE
*
D
:DUAL
H
:208/230-3-60
M
:380-3-60
(4 WIRE)
F
:460-3-60
A
: STANDARD UNIT &
ECONOMIZER
B
: LOW CFM & 100%
FRESH AIR UNIT
****
MODEL DECODING
9
COMPRESSOR
TYPE
S
:SCROLL
(UP TO PDS600)
H
:SEMI-
HERMETIC
RECIPROCAT-
ING
L
:SEMI-
HERMETIC
RECIPROCAT-
ING WITH
CAPACITY
CONTROL
**
14
E
V
APORA
TO
R
COIL
17
BLOWER MOT
OR
18
DRIVE OPTIONS
20
INDOOR
AIR QUALITY (
IA
Q
)
19
H
E
A
TER OPTIONS
(kW/STAGES)
A
: 1 HP TEFC
B
:
1.5 HP TEFC
C
: 2 HP TEFC.
D
: 3 HP TEFC
E
: 5 HP TEFC
F
:
7.5 HP TEFC
G
: 10 HP TEFC
H
: 15 HP TEFC
I
:
20 HP TEFC
J
: 25 HP TEFC
K
: 30 HP TEFC
A
: ALT. I
B
: ALT. II
C
: ALT. III
A
:
STD. OPTIONS
***
B
:
BAG FILTER & 2" THICK ALUMINUM PRE-FILTER
D
:
2" THICK ALUMINUM FILTER
U
:
ULTRA VIOLET LAMPS
M
:
ECONOMIZER CONTROL WITH OUTSIDE AIR THERMO-
STAT (PSYCHROTROLL)
L
:
ECONOMIZER CONTROL WITH ENTHALPY SENSOR
H
:
ECONOMIZER CONTROL WITH ENTHALPY SENSOR
&
CO
2
MONITOR
K
:
D & U COMBO
G
:
D & M COMBO
R
:
D & L COMBO
S
:
D & H COMBO
T
:
B & U COMBO
E
:
B & M COMBO
F
:
B & L COMBO
J
:
B & H COMBO
N
:
D, M & U COMBO
P
:
D, L & U COMBO
V
:
D, H & U COMBO
I
:
B, M & U COMBO
Y
:
B, L & U COMBO
Z
:
B, H & U COMBO
N
:NO HEATER
A
:5/1
B
:6/1
C
:7.5/1
D
:10/2
F
:15/2
G
:20/2
H
:25/2
J
:30/2
L
:40/2
M
:50/2
P
:60/2
NOTES
:
*
–
Single scroll compressors for models PDS036-PDS075 (single circuit) & single semi-hermetic compressors up to models PDS150 (si
ngle circuit). All other models are with dual compressors (dual circuit).
**
–
Capacity control options starts from units PDS060 onwards.
***
–
Standard options contains vibration eliminator (for semi-hermetic), fixed high/low pressure switches, fan cycling (low ambient
) switches and UVM .
****
–
To select low CFM & 100% fresh air units, follow the software selection procedure.
A
:
ALUMINUM
FIN
B
:
COATED
ALUMINUM
FIN
C
:
COPPER
FIN
D
:
HERESITE
COATING
WITH ALUMINUM
FIN
H
:
HERESITE
COATING
WITH COPPER FIN
S
TANDARD UNIT &
ECONOMIZER
A
:
ALUMINUM
FIN
B
:
COATED
ALUMINUM FIN
C
:
COPPER
FIN
LOW CFM & 100% FRESH
AIR UNIT
J
:
ALUMINUM
FIN
K
:
COATED
ALUMINUM FIN
L
:COPPER
FIN
NOTE:
The oracle system al-
lows to select 5, 6, 8, 10 or
12 rows. Please order correct
number of rows according to
the selection software.
11
KITS
ELECTRICAL OPTIONS
A
: STD.
***
C
:
COMP. CIRCUIT BREAKER
K
: ADJUSTABLE LOW & HIGH
PRESSURE SWITCHES AND
FAN CYCLING SWITCH
P
: PUMP DOWN SOLENOID
VALVE
V
:
VOLT FREE CONTACT &
ANTI-ICE
B
: K & V COMBO
E
: K & C COMBO
G
: K & P COMBO
L
: K, C & P COMBO
M
: K, V & P COMBO
N
: V, C & P COMBO
T
: K, V & C COMBO
R
: K, V, C & P COMBO
16
SUPPL
Y
AIRFLOW
T
:TOP
F
:FRONT
15
RETURN & FRESH
AIRFLOW
S
TANDARD UNIT & ECONOMIZER
T
:TOP RETURN & SIDE FRESH AIR
B
:BOTTOM RETURN & SIDE FRESH AIR
S
:SIDE RETURN & SIDE FRESH AIR
R
:REAR RETURN & SIDE FRESH AIR
(MIDDLE FAN)
LOW CFM & 100%
FRESH
AIR UNIT
M
:TOP FRESH AIR (100% FRESH AIR)
L
:SIDE FRESH AIR (100% FRESH AIR)
K
:REAR FRESH AIR (100% FRESH AIR)
(MIDDLE FAN)
E
:TOP RETURN & SIDE FRESH AIR
C
:SIDE RETURN & SIDE FRESH AIR
N
:REAR RETURN & SIDE FRESH AIR
(MIDDLE FAN)
12
KITS
MECHANICAL OPTIONS
A
: STD.
***
D
: DISCHARGE GAS
SENSOR
E
: DRIP ELIMINATOR
H
:
HOT GAS BYPASS
VALVE
M
:
REPLACEABLE
FILTER
DRIER, MUFFLER, BALL
VALVE & GAUGES
B
: M & H COMBO
G
: M & E COMBO
T
: M & D COMBO
K
: M, H & D COMBO
L
: M, E & D COMBO
N
: H, E & D COMBO
S
: M, H & E COMBO