8
WIRING SPECIFICATIONS
The system supports two electric catch release configurations: with the open command sent
by (i) an entrance panel or (ii) a system display (the display open command output wire must
have the shield connected to earth).
If the open command is sent by an entrance panel, use this wiring specification:
•
If the entrance panel is < 30 m away from the video entry phone display,
use YTDYw 4 x 0.5 mm
2
wiring.
RED
BLUE
YELLOW
WHITE
1
2
3
4
1
2
3
4
RED
BLUE
YELLOW
WHITE
GREEN
BROWN
ELECTRIC
CATCH
ENTRANCE PANEL
•
If the entrance panel is > 30 m away from the video entry phone display,
use YTDYw 4 x 0.5 mm
2
wiring.
RED
BLUE
YELLOW
WHITE
1
2
3
4
1
2
3
4
RED
BLUE
YELLOW
WHITE
GRÜN
BRAUN
ELECTRIC
CATCH
ENTRANCE PANEL
If the open command is sent by a display, use this wiring specification:
•
If the entrance panel is < 30 m away from the video entry phone display,
use YTDYw 6 x 0.5 mm
2
wiring.
ENTRANCE PANEL
ELECTRIC CATCH
BLACK
GREEN
RED
BLUE
YELLOW
WHITE
RED
BLUE
YELLOW
WHITE
BRAUN
•
If the entrance panel is < 30 m away from the video entry phone display,
use YTDYw 6 x 0.8 mm
2
wiring.
ENTRANCE PANEL
ELECTRIC CATCH
BLACK
GREEN
RED
BLUE
YELLOW
WHITE
RED
BLUE
YELLOW
WHITE
BRAUN
GREEN
GREEN
DISPLAY
DISPLAY
DISPLAY
DISPLAY