XP8600/XP8900
92
s
Simulated PLCBus Connections
(
BL1400 and BL1500
Expansion boards may be connected to header H3 on the BL1400 and
BL1500. The signals, listed in Table D-1, are laid out differently from
those on the other controllers, and so the special cable used for the
BL1000, the BL1100, or the BL1300 controllers will not work. The user
may either make a custom cable or use an adapter board available from
Z-World. Software from the Dynamic C
EZIOMGPL.LIB
library may be
used.
Use an external power supply with expansion boards con-
nected to the BL1400 or BL1500. There is no provision to
supply power from the controller to header P1 or P2 on the
expansion boards. The adapter board has a jack and a screw
terminal for the ex12 V/+24 V.
For more information on the adapter board, call your Z-World
Sales Representative at (530) 757-3737.
Table D-1. PIO Header to PLCBus Signal Map
BL1400/BL1500
Expansion Board
Header H3 Pin
PIO Port Signal
Header P1/P2 Pin
PLCBus Signal
1
+5 V
2
+5 V
2
PA0
5
/STBX
3
PA1
19
D0X
4
PA2
20
D1X
5
PA3
17
D2X
6
PA4
18
D3X
7
PA5
11
A1X
8
PA6
9
A2X
9
PA7
7
A3X
10
GND
10
GND
!
Summary of Contents for XP8600
Page 6: ...vi s Table of Contents XP8600 XP8900 Blank ...
Page 10: ...XP8600 XP8900 x s About This Manual Blank ...
Page 11: ...XP8600 ...
Page 12: ...This page is blank intentionally Blank ...
Page 20: ...XP8600 20 s Getting Started Blank ...
Page 26: ...XP8600 26 s I O Configurations Blank ...
Page 38: ...XP8600 38 s Software Reference Blank ...
Page 39: ...XP8900 ...
Page 40: ...This page is blank intentionally Blank ...
Page 48: ...XP8900 48 s Getting Started Blank ...
Page 52: ...XP8900 52 s I O Configurations Blank ...
Page 64: ...XP8900 64 s Software Reference Blank ...
Page 65: ...APPENDICES ...
Page 66: ...This page is blank intentionally Blank ...
Page 78: ...XP8600 XP8900 78 s PLCBus Blank ...
Page 79: ...XP8600 XP8900 Specifications s 79 APPENDIX B SPECIFICATIONS ...
Page 84: ...XP8600 XP8900 84 s Specifications Blank ...
Page 89: ...XP8600 XP8900 Simulated PLCBus Connections s 89 APPENDIX D SIMULATED PLCBUS CONNECTIONS ...