background image

Refrigerator Multi-Sensor                    
PAT13-A/B                                                     

The   refrigerator   temperature   sensor   PAT13   has   temperature   and
door/window   ,   2   sensors   function   in   one,   based   on  Z-Wave

TM

technology.
It is the  Z-Wave

TM

  plus product, it support the security, OTA... Those

newest   features   of   the  Z-Wave

TM

  technology.  Z-Wave

TM

  is  a   wireless

communication protocol designed for home automation, specifically to
remotely   control   applications   in   residential   and   light   commercial
environments. The technology uses a low-power RF radio embedded or
retrofitted into home electronics devices and systems, such as lighting,
home access control, entertainment systems and household appliances.

This product can be included and operated in any Z-Wave

TM

  network

with other Z-Wave

TM

 certified devices from other manufacturers and/or

other applications.  All non-battery operated nodes within the network
will act as repeaters regardless of vendor to increase reliability of the
network. 

The device adopt the Z-Wave

TM

  500 series chip, when your Z-Wave

TM

network   system   is   all   made   by   Z-Wave

TM

  500   series   devices.   The

network system will have the advantages as below.

Concurrent multi-channel support reduces external interference.

Better RF range, improve about 10 meters in indoor.

Support 100 Kbps transmit speed, speed up communication.

Specification

Rated

DC3V (CR123A)

RF distance

Min. 40M indoor,
100M outdoor line of sight,

RF Frequency

868.40 MHz, 869.85 MHz(EU)
908.40 MHz, 916.00 MHz(US)
920.9MHz, 921.7MHz, 
923.1MHz(TW/SG/Thai/KR)

RF Maximum Power 

+10dBm (Peak), -10dBm 
(Average)

Dimension

85(L)x 28(W)x23(H) mm 

Weight

80g

IP classification

IP20; indoor use

Operation temperature

-10 to 40° C

Humidity

85%RH max

Magnetic gap

25mm (open to close); 30mm 
(close to open)

Temperature Detect Range

-30 to 100°C

Cable type

28AWGx 4C OD: 3.0mm, 2 
meters, -40 to 80 °C

FCC ID

RHHPAT13

1

Summary of Contents for PAT13-A

Page 1: ...ll non battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network The device adopt the Z WaveTM 500 series chip when your Z WaveTM netw...

Page 2: ...ooting Symptom Cause of Failure Recommendation The device can not join to Z Wave network The device may in a Z Wave network Exclude the device then include again For Instruction to http www philio tec...

Page 3: ...onds to enter the exclusion mode Node ID has been excluded Reset Notice Use this procedure only in the event that the primary controller is lost or otherwise inoperable 1 Pressing tamper key four time...

Page 4: ...x06 Event Door Window Open 0x16 And after the Door Window Close clear the device will unsolicited to send the report to the nodes in the lifeline group Notification Report V4 Notification Type Access...

Page 5: ...ort except the low battery detection Power Up Procedure Battery Power Check When the device power up the device will detect the power level of the battery immediately If the power level is too low the...

Page 6: ...tory default Unless the user execute the RESET procedure The reserve bit or not supported bit is allowed any value but no effect NO Name Def Vali d A B Description 1 Basic Set OFF Level 0 All Setting...

Page 7: ...t the battery level 0 means turn off auto report The default value is 12 The tick time can setting by the configuration No 20 11 Auto Report Door Win dow State Time 12 0 127 The interval time for auto...

Page 8: ...granted Security Class Wake Up 2 Highest granted Security Class Association Group Info 1 Highest granted Security Class Powerlevel 1 Highest granted Security Class Device Reset Locally 1 Highest grant...

Page 9: ...ned by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation be...

Reviews: