background image

NO

.

Name

Def.

Vali

A

B

Description

0

Bit1

: Reserve.

0

Bit2

: Disable the door/window 

function.

0

Bit3

: Setting the temperature 

scale.
  0: Fahrenheit, 1:Celsius

0

Bit4

: Reserve.

0

Bit5

: Disable the temperature 

report after event triggered.  
(1:Disable, 0:Enable)

0

Bit6

: Reserve.

0

Bit7

: Reserve.

7

(*)

Customer
Function

All

0

0

Customer function switch, using bit
control.

0

Bit0

: Reserve.

0

Bit1

: Reserve.

0

Bit2

: Reserve.

0

Bit3

: Disable send out BASIC OFF 

after the door/window event 
cleared. (1:Disable, 0:Enable)

0

Bit4

: Reserve.

0

Bit5

: Reserve.

0

Bit6

: Disable to report battery 

state when the device triggered. 
(1:Disable, 0:Enable)

0

Bit7

: Reserve.

NO

.

Name

Def.

Vali

A

B

Description

10

Auto 
Report 
Battery 
Time

12

0 ~
127

The interval time for auto report 
the battery level. 
0 means turn off auto report.
The default value is 12. The tick 
time can setting by the 
configuration No.20.

11

Auto 
Report  
Door/Win
dow State
Time

12

0 ~
127

The interval time for auto report 
the door/window state. 
0 means turn off auto report 
door/window state.
The default value is 12. The tick 
time can setting by the 
configuration No.20.

13

Auto 
Report 
Temperat
ure Time

12

0 ~
127

The interval time for auto report 
the temperature. 
0 means turn off auto report.
The default value is 12. The tick 
time can setting by the 
configuration No.20.

20

Auto 
Report 
Tick 
Interval

30

0 ~
0xF

F

The interval time for auto report 
each tick. Setting this configuration
will effect configuration No.10, 
No.13, No.14 and No.15.
Units of one minute.

Caution1

Setting to 

0

 means 

turn off all auto report function.

Caution2

: The value is unsigned 

byte, the range is from 0x00 ~ 
0xFF.

21 Temperat

1

0 ~

The temperature differential to 

7

Summary of Contents for PAT13-A

Page 1: ...ll non battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network The device adopt the Z WaveTM 500 series chip when your Z WaveTM netw...

Page 2: ...ooting Symptom Cause of Failure Recommendation The device can not join to Z Wave network The device may in a Z Wave network Exclude the device then include again For Instruction to http www philio tec...

Page 3: ...onds to enter the exclusion mode Node ID has been excluded Reset Notice Use this procedure only in the event that the primary controller is lost or otherwise inoperable 1 Pressing tamper key four time...

Page 4: ...x06 Event Door Window Open 0x16 And after the Door Window Close clear the device will unsolicited to send the report to the nodes in the lifeline group Notification Report V4 Notification Type Access...

Page 5: ...ort except the low battery detection Power Up Procedure Battery Power Check When the device power up the device will detect the power level of the battery immediately If the power level is too low the...

Page 6: ...tory default Unless the user execute the RESET procedure The reserve bit or not supported bit is allowed any value but no effect NO Name Def Vali d A B Description 1 Basic Set OFF Level 0 All Setting...

Page 7: ...t the battery level 0 means turn off auto report The default value is 12 The tick time can setting by the configuration No 20 11 Auto Report Door Win dow State Time 12 0 127 The interval time for auto...

Page 8: ...granted Security Class Wake Up 2 Highest granted Security Class Association Group Info 1 Highest granted Security Class Powerlevel 1 Highest granted Security Class Device Reset Locally 1 Highest grant...

Page 9: ...ned by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation be...

Reviews: