Name

Def.

Vali

A

B

Description

ure 
Differenti
al Report

127

report.
0 means turn off this function. 
The unit is Fahrenheit.
Enable this function the device will 
detect every 10 seconds. 
And when the temperature is over 
140 degree Fahrenheit, it will 
continue report.

Z-Wave Supported Command Class

Command Class

Version

Required Security Class

Z-Wave Plus Info

2

None

Battery

1

Highest granted Security Class

Notification

8

Highest granted Security Class

Association

2

Highest granted Security Class

Configuration

1

Highest granted Security Class

Manufacturer Specific

2

Highest granted Security Class

Version

3

Highest granted Security Class

Sensor Multilevel

11

Highest granted Security Class

Wake Up

2

Highest granted Security Class

Association Group Info

1

Highest granted Security Class

Powerlevel

1

Highest granted Security Class

Device Reset Locally

1

Highest granted Security Class

Security 0

1

None

Security 2

1

None

Firmware Update Meta Data

4

Highest granted Security Class

Supervision

1

None

Transport Service

2

None

Basic

1

Highest granted Security Class

CAUTION
Risk of explosion if battery is replaced by an incorrect type.
Dispose of used battery according to the instructions.

Choosing a Suitable Location

1.

The   suitable   ambient   temperature   for   the   module/device   is
0°C~40°C.

2. Do NOT place the module/device direct under sunlight, in a humid

place or in any location where they may contact moisture, dirt, dust.

3.

Do   NOT   place   the   module/device   where   exists   combustible
substances or any source of heat, fires, radiators, boiler etc.

8

Summary of Contents for PAT13-A

Page 1: ...ll non battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network The device adopt the Z WaveTM 500 series chip when your Z WaveTM netw...

Page 2: ...ooting Symptom Cause of Failure Recommendation The device can not join to Z Wave network The device may in a Z Wave network Exclude the device then include again For Instruction to http www philio tec...

Page 3: ...onds to enter the exclusion mode Node ID has been excluded Reset Notice Use this procedure only in the event that the primary controller is lost or otherwise inoperable 1 Pressing tamper key four time...

Page 4: ...x06 Event Door Window Open 0x16 And after the Door Window Close clear the device will unsolicited to send the report to the nodes in the lifeline group Notification Report V4 Notification Type Access...

Page 5: ...ort except the low battery detection Power Up Procedure Battery Power Check When the device power up the device will detect the power level of the battery immediately If the power level is too low the...

Page 6: ...tory default Unless the user execute the RESET procedure The reserve bit or not supported bit is allowed any value but no effect NO Name Def Vali d A B Description 1 Basic Set OFF Level 0 All Setting...

Page 7: ...t the battery level 0 means turn off auto report The default value is 12 The tick time can setting by the configuration No 20 11 Auto Report Door Win dow State Time 12 0 127 The interval time for auto...

Page 8: ...granted Security Class Wake Up 2 Highest granted Security Class Association Group Info 1 Highest granted Security Class Powerlevel 1 Highest granted Security Class Device Reset Locally 1 Highest grant...

Page 9: ...ned by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation be...

Reviews: