background image

GARO TWIN+

Box 203, SE–335 25 Gnosjö
Phone: +46 (0) 370 33 28 00
[email protected]

garo.se

Manual 380237

Assembly instructions / End User Instruction (EN)

GARO AB

EN

Summary of Contents for TWIN+

Page 1: ...GARO TWIN Box 203 SE 335 25 Gnosj Phone 46 0 370 33 28 00 info garo se garo se Manual 380237 Assembly instructions End User Instruction EN GARO AB EN...

Page 2: ...T About this manual 3 INFORMATION 3 Warnings 3 Cautions 4 Notes 4 Content 5 INSTALLATION 6 Dimensional sketch 11 USER MANUAL 12 Normal use 12 LED indications 12 Technical specifications 13 Electrical...

Page 3: ...WIN must be grounded according to local country installation requirements Do not install or use the TWIN near flammable explosive harsh or combustible materials chemicals or vapors Turn off the electr...

Page 4: ...pped on or subjected to damage or stress Unroll the charging cable to prevent it from overheating Do not use cleaning solvents to clean any of the components The outside of the TWIN the charging cable...

Page 5: ...INFORMATION GARO TWIN Box 203 SE 335 25 Gnosj Phone 46 0 370 33 28 00 info garo se garo se Manual 380237 Installation Instruktionsmanual GARO AB SE Manual TWIN 3X 3X Keys Content 5 EN...

Page 6: ...to consider the cable length during calculation to avoid risk of voltage drop Note Due to high currents for a long time in the cable there is a high risk of voltage drop if the cable is under dimensi...

Page 7: ...LLATION picture 4 picture 5 picture 6 Note Wall installation requires a minimum 20mm distance between the wall and the TWIN to ensure correct cooling see picture 3 When TWIN is installed on a pole the...

Page 8: ...installed to same mains For example 1st TWIN L1 L2 L3 2nd TWIN L3 L1 L2 3rd TWIN L2 L3 L1 And so on Note When DLM is pre configurated from factory follow the marked phase order label at incoming termi...

Page 9: ...een each TWIN and the provided ethernet router switch located ie in GARO KOMM BOX Se example of ethernet wiring diagram picture 10 Note Connect the ethernet cable to CC1 The ethernetport on CC2 is not...

Page 10: ...protection cover and close the front door Picture 11 11 Turn on electrical power 12 Wait a few minutes until the TWIN have finished the startup process and test both sides with a EVSE tester or an EV...

Page 11: ...INSTALLATION 660 377 206 Dimensional sketch 11 EN...

Page 12: ...uctions After charging Release the charging cable from your EV and place the charging cable at designated place LED indications Fels kning Support FAQ mm www garoemobility com support 3pcs green flash...

Page 13: ...AC Charging Protection class IP44 Mechanical impact resistance IK10 Temperature range 25C 40C Weight 14 18kg depending on model Standard cable length fixed cable version Standard 4m Rated current with...

Page 14: ...utlet FB2 RCCB Right Outlet FC1 Fuse Left Outlet FC2 Fuse Right Outlet FC3 Fuse Charge Controller and Powersupply QA1 Contactor Left Outlet QA2 Contactor Right Outlet XN1 N Neutral terminal XPE1 PE Te...

Page 15: ...B1 40A N 5 1 3 2 4 mA 30 14 13 N 6 FB2 40A N 5 1 3 2 4 mA 30 14 13 I 32A FC2 5 6 7 8 1 2 3 4 24 23 I 32A FC1 5 6 7 8 1 2 3 4 24 23 AC PLINT CC1 Relais 24 CC2 Relais 24 CC2 A Mod CC2 B Modbus CC1 A Mod...

Page 16: ...USER MANUAL L1 N 12V DC 230 V T1 CC1 Relais 23 CC2 Relais 23 12V 0V 1 SVART BLACK 1mm R D RED 1mm KF1 0V KF1 12V CC1 0V CC2 0V CC1 12V CC2 12V 1 1 1 5 AC PLINT FC3 Noll Plint Jord Plint 16 EN...

Page 17: ...r HS2 Relais 14 GND2 Modbus B2 Modbus A2 Modbus WA Relais 23 WA Relais 24 Eth 1 10 100 RJ45 Purple Purple Dark Blue Dark Blue White White Green Green R17 R18 R19 R20 HEAT FB1 13 FB1 14 FC1 23 FC1 24 F...

Page 18: ...1 CC2 Charge Controller 2 QA1 Contactor Left Outlet Connector 1 QA2 Contactor Right Outlet Connector 2 X1 Incoming terminal 1 FC1 Fuse Left Outlet Connector 1 FB1 RCCB Left Outlet Connector 1 P1 Energ...

Page 19: ...ional tests Specific service points can be found in the service form If your TWIN is connected to Backend Operator or other external supervised system GARO recommends that you contact the operator to...

Page 20: ...est by GARO test equipment or similar Check that electrical power is delivered by indications on test equipment Check RFID reader when available Indication by 2 or 3 flashes from LED s Check Type 2 so...

Page 21: ...anty form by an certified installer contractor If the original installation date cannot be verified then the warranty period begins ninety 90 days from the date of product manufacture as indicated by...

Page 22: ...nr ELECTRICAL INSTALLATION DATA Group fuse Grupps kring A Supply cable dimension Kabelarea FUNCTION TEST Testbox EV model Date Datum Sign Installer Sign installat r Company Name F retagsnamn Owner Cus...

Page 23: ...GARO AB Box 203 SE 335 25 Gnosj Phone 46 0 370 33 28 00 info garo se garo se EN...

Reviews: